Datasheet

www.recom-power.com
REV.: 3/2019 ECO-2
DC/DC Converter
RS3-S(D)(Z)
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Model Numbering
Isolation
(2)
2:1 or 3:1 Input
(3)
nom. Input Voltage
Output Voltage
Single or Dual
RS3- /
Ordering Examples:
RS3-053.3S 4.5-9Vin 3.3Vout Single 2:1 Input Voltage 1kVDC Isolation
RS3-1212D/H2 9-18Vin ±12Vout Dual 2:1 Input Voltage 2kVDC Isolation
RS3-2415D/H3 9-27Vin ±15Vout Dual 3:1 Input Voltage 3kVDC Isolation
Notes:
Note2: add „Z“ for 3:1 Input Voltage (24= 9-27VDC or 48= 20-60VDC)
Note3: add suffix „/H2“ for 2kVDC isolation or „/H3“ for 3kVDC isolation, without suffix = standard 1kVDC isolation
BASIC CHARACTERISTICS
Parameter Condition Min. Typ. Max.
Input Voltage Range
2:1 Input nom. Vin=
5VDC
12VDC
24VDC
48VDC
4.5VDC
9VDC
18VDC
36VDC
9VDC
18VDC
36VDC
72VDC
3:1 Input nom. Vin=
24VDC
48VDC
9VDC
20VDC
27VDC
60VDC
Quiescent Current nom. Vin=
5VDC
12VDC
24VDC
48VDC
35mA
25mA
20mA
10mA
Minimum Load
(4)
10%
ON/OFF CTRL
DC-DC ON
DC-DC OFF
open or high impedance
external V
CTRL
= 5-12VDC + 1N4148 and 68W resistor
Internal Operating Frequency 20% to 100% full load
200kHz
Output Ripple and Noise
20MHz BW 50mVp-p
continued on next page
Notes:
Note4: Operation below 10% load won‘t harm the converter, but specifications may not be met
Efficiency vs. Load
RS3-0505S RS3-4805D
0 10 20 30 40 50 60 70 80 90 100
100
80
60
40
90
70
50
30
20
10
0
Efficiency [%]
Output Load [%]
0 10 20 30 40 50 60 70 80 90 100
100
80
60
40
90
70
50
30
20
10
0
Efficiency [%]