Part Number Input Rated Output Output Current Efficiency Max
Voltage Range Voltage Full Load typ. Capacitive
SIP8 (VDC) (VDC) (mA) (%) Load
(1)
RS3-xx3.3S (H2/H3) 4.5-9, 9-18 3.3 600 73-75 4700µF
18-36, 36-72 77-78
RS3-xx05S (H2/H3) 4.5-9, 9-18 5 600 76-79 4700µF
18-36, 36-72 80-81
RS3-xx09S (H2/H3) 4.5-9, 9-18 9 333 77-80 3300µF
18-36, 36-72 81-82
RS3-xx12S (H2/H3) 4.5-9, 9-18 12 250 80-81 2200µF
18-36, 36-72 83
RS3-xx15S (H2/H3) 4.5-9, 9-18 15 200 80-81 2200µF
18-36, 36-72 83
RS3-xx3.3D (H2/H3) 4.5-9, 9-18 ±3.3 ±300 73-75 ±2200µF
18-36, 36-72 75
RS3-xx05D (H2/H3) 4.5-9, 9-18 ±5 ±300 76-80 ±2200µF
18-36, 36-72 80-81
RS3-xx09D (H2/H3) 4.5-9, 9-18 ±9 ±167 77-81 ±2200µF
18-36, 36-72 81
RS3-xx12D (H2/H3) 4.5-9, 9-18 ±12 ±125 78-83 ±1000µF
18-36, 36-72 83
RS3-xx15D (H2/H3) 4.5-9, 9-18 ±15 ±100 79-83 ±1000µF
18-36, 36-72 83
RS3-xx3.3SZ (H2/H3) 9-27 3.3 600 73 4700µF
20-60 74
RS3-xx05SZ (H2/H3) 9-27 5 600 76-79 4700µF
20-60 78
RS3-xx09SZ (H2/H3) 9-27 9 333 77 3300µF
20-60 79
RS3-xx12SZ (H2/H3) 9-27 12 250 80 2200µF
20-60 80
RS3-xx15SZ (H2/H3) 9-27 15 200 80 2200µF
20-60 80
RS3-xx3.3DZ (H2/H3) 9-27 ±3.3 ±300 73 ±2200µF
20-60 74
RS3-xx05DZ (H2/H3) 9-27 ±5 ±300 77 ±2200µF
20-60 78
RS3-xx09DZ (H2/H3) 9-27 ±9 ±167 79 ±2200µF
20-60 79
RS3-xx12DZ (H2/H3) 9-27 ±12 ±125 80 ±1000µF
20-60 80
RS3-xx15DZ (H2/H3) 9-27 ±15 ±100 80 ±1000µF
20-60 80
No suffix is standard isolation (1kVDC) e.g, RS3-0505S
*add suffix /H2 or /H3 for 2kVDC or 3kVDC isolation, e.g, RS3-0505S/H2, R3S-0505DZ/H3
3 Watt
SIP8 Isolated
Single
& Dual
Output
2:1 and 3:1 Wide Input Voltage Ranges
1kVDC, 2kVDC and3kVDC Isolation
UL94V-0 Package Material
Continuous Short Circuit Protection
Low Ripple and Noise
Remote On/Off Control
Efficiency to 83%
Features
Regulated
Converters
Selection Guide
Description
2:1 Input 3:1 Input
(RS3-S/D) (RS3-SZ/DZ)
xx = 4.5-9Vin = 05 xx = 9-27Vin = 24
xx = 9-18Vin = 12 xx = 20-60Vin = 48
xx = 18-36Vin = 24
xx = 36-72Vin = 48
EN-60950-1 Certified
EN-60601-1 Certified
(Suffix /H3)
Very high power density, 2:1 or 3:1 input voltage range and a wide operating temperature
range -40°C~+71°C and extra features such as On/Off control are just some of the cha-
racteristics of this converter which is ideal for highly sophisticated industrial designs.The
RS3 is available with 2kV or 3kV isolation options (1kVDC is standard)
Refer to Application Notes
RoHS
2002/95/EC
6/6