Data Sheet
Output Power (%)
100
60
20
40
100500-40
85
150
Operating Temperature °C
0
80
Safe Operating Area
30
Derating-Graph
(Ambient Temperature)
Typical Characteristics
Description
Input Voltage Range 2:1
Output Accuracy Single output ±1%
Dual output ±2%
Line Voltage Regulation Single output ±0.2% max.
Dual output ±0.5% max.
Load Voltage Regulation Single & Dual output ±0.5% typ.
(25% to 100% full load)
Output Ripple and Noise (20MHz limited) 50mVp-p max.
Switching Frequency (at full Load) Single output 85kHz min.
Dual output 100kHz min. / 700kHz max.
Efficiency at Full Load 70% min. / 80% typ.
No Load Power Consumption 50mW min. / 139mW typ. / 250mW max.
Isolation Voltage (tested for 1 second) 1000VDC min.
H2 2000VDC min.
H3 3000VDC min.
Rated Working Voltage (long term isolation) see Application Notes
Isolation Capacitance (1000V version) Single 10pF min. / 40pF typ. / 60pF max.
Isolation Capacitance (H2 and H3) Single 5pF min. / 30pF typ. / 60pF max.
Isolation Capacitance (1000V version) Dual 120pF min. / 170pF typ. / 250pF max.
Isolation Capacitance (H2 and H3) Dual 5pF min. / 30pF typ. / 60pF max.
Isolation Resistance 1GΩ min.
Short Circuit Protection Continuous
Operating Temperature Range –40°C to +85°C
Storage Temperature Range –55°C to +125°C
Relative Humidity 95% RH
Package Weight 4.8g
MTBF (+25°C) using MIL-HDBK 217F 1398 x 10
3
hours
(+85°C) using MIL-HDBK 217F 210 x 10
3
hours
Electrical Specifications (measured at T
A
= 25°C, at nominal input voltage and rated output current unless otherwise specified)
RS
Series
ECONOLINE
DC/DC-Converter
Efficiency %
100
0
40%0% 100%
40
Efficiency / Load
60%
80%
20%
20
60
80
Total Output current (%)
2405
2412
2409
2415
RS-24xx
Output Power (W)
2
0
64.5
1.70
7
85
0.5
1
1.5
Input Voltage (V)
9
RS-types
High power-density, an industrial temperature range of -40°C to +85°C and extra features like Remote-On-
Off-control are just some of the characteristics of this converter, ideal for highly sophisticated industrial
designs. The RS series is available with isolation of 2kV or 3kV by chosing option "/H2" or "/H3" in which case
it is also ideal for medical applications which additionally require EN-60601-1 certification.
}
Detailed Information see
Application Notes chapter "MTBF"
January-2007 89www.recom-international.com