Datasheet
www.recom-power.com
REV.: 1/2019 RPX-3
DC/DC Converter
RPX-2.5
Series
Specifications (measured @ ta= 25°C, 12Vin, 3.3Vout, full load and after warm-up unless otherwise stated, refer to test set up)
UNDER VOLTAGE LOCKOUT SETTING
The RPX-2.5 features an internal UVLO circuit that disables the converter until the input voltage exceeds 4.1V typ. This threshold can be raised by adding
an external resistor divider R
UVLO1
and R
UVLO2
.
Standard Resistor Values
VIN UVLO [VDC] 4.5 10 15 18 20
R
UVLO1
[kW] 68.1 68.1 68.1 68.1 68.1
R
UVLO2
[kW] 25.5 9.53 6.04 4.99 4.42
V
OUT
+V
out
FB
R
FBT
open open
R
FBB
V
IN
V
IN
DNC SW
CTRL
GND
RPX-2.5
R
ULVO1
R
UVLO2
C
IN1
C
IN2
C
OUT1
C
FF
C
OUTn
. . .
Efficiency vs. output current
Vout= 3.3VDC, Vin= 12VDC (2.5A max)
Vout= 3.3VDC, Vin= 24VDC (2.0A max) Vout= 5VDC, Vin= 24VDC (2.1A max.)
Vout= 5VDC, Vin= 12VDC (2.5A max)
0 10 20 30 40 50 60 70 80 90
100
100
80
60
40
90
70
50
30
20
10
0
Efficiency [%]
Output Load [%]
0 10 20 30 40 50 60 70 80 90
100
100
80
60
40
90
70
50
30
20
10
0
Efficiency [%]
Output Load [%]
0 10 20 30 40 50 60 70 80 90
100
100
80
60
40
90
70
50
30
20
10
0
Efficiency [%]
Output Load [%]
0 10 20 30 40 50 60 70 80 90
100
100
80
60
40
90
70
50
30
20
10
0
Efficiency [%]
Output Load [%]