Datasheet

www.recom-power.com
REV.: 0/2019 P-1
RPMB-3.0-EVM-1
Evaluation Module
Features
Evaluation
Module
Evaluation platform for RPMB-3.0 Power Modules
Thermal design considerations included
EMI Class B filter
Easy evaluation of control, power good and
sensing functions
Description
The RPMB-3.0-EVM-1 generates a constant output voltage with an output current up to 3.0A from an
external DC source. Functions of the RPMB-3.0 such as trimming, control, and sensing can be evalu-
ated. Also the behavior in overload or over temperature can be evaluated easily before it design-in.
Caution:
ESD sensitive. Always follow ESD preventative procedures when
handling the product!
Quick Start Guide
1) Connect P1 to power supply (observe correct polarity!)
2) Connect P2 to a Load
3) Connect sense to the required potential
The sense preset is via R1 directly at the power module, so the preset voltage is very accurate at the
output of the RPMB-3.0. To equalize ohmic losses of the output filter, remove the resistor at R1, and
solder a 0 resistor at R2.
4) Disable the device via R5
The device is preset as normally on. It can be disabled by pulling the CTRL pad to GND.
Short R5 to disable the device.
Selection Guide
Part
Number
Input Voltage
Range
[VDC]
nom. Output
Voltage
[VDC]
Vout
Adjust Range
[VDC]
Output
Current max.
[A]
RPMB3.3-3.0-EVM-1 4-36 3.3 1-9 3.0
RPMB5.0-3.0-EVM-1 5.5-36 5 1-9 3.0
RPMB12-3.0-EVM-1 12.8-36 12 9-24 3.0
RPMB15-3.0-EVM-1 16-36 15 9-24 3.0
Preliminary