Datasheet
www.recom-power.com
REV.: 1/2019 PB-3
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RP40Q-RUW
Series
8
6
4
2
7
5
3
1
0
Power Dissipation [W]
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
24Vin
36Vin
48Vin
72Vin
110Vin
RP40Q-11005SRW
Power Dissipation vs. Output Current
Power up Start-up Rise CharacteristicON/OFF Control Start up Rise Characteristic
Typical Output Ripple and Noise/full load
Input Voltage [VDC]
Output Power [%]
100
0
0.1s <1scontinuous operation
14.0 16.0 185160
Input Voltage Range
Continuous full power operation is rated between 16V and 160V,
including full load start-up.
Once running, the converter will operate for short periods of time over
an extended input voltage range down to 14V and up to 185V, thus
covering all EN50155 under-voltage and over-voltage transient
conditions.