Datasheet

DC/DC Converter
PROTECTIONS
Parameter Condition Value
Short Circuit Protection (SCP) Continuous, automatic recovery
Over Voltage Protection (OVP) Zener Diode Clamp
5Vout
12Vout
15Vout
6.2VDC
15VDC
18VDC
Over Load Protection (OLP) %of Iout rated 150% typ.
Isolation Voltage
I/P to O/P
I/P (O/P) to case
1.6kVDC/1 minute
1.6kVDC/1 minute
Isolation Resistance 500VDC 1G
Ω
min.
Isolation Capacitance 300pF max.
Specifications measured at Ta = 25°C, nominal input voltage, full load otherwise noted
REGULATIONS
Parameter Condition Value
Output Voltage Accuracy ±1%
Load Voltage Regulation 0% to 100% load
Single
Dual
±0.5%
±1.0%
Line Voltage Regulation low line to high line, full load ±0.2%
Cross Regulation asymmetrical 25%<>100% load ±5%
Transient Response recovery time 25% load step change 250μs
RP10-EW
Series
PD-3
REV.: 3/2016www.recom-power.com
Efficiency vs. Output Current Efficiency vs. Input Voltage
18Vin
48Vin
75Vin
Efficiency [%]
Output Current [%]
10
60
55
50
45
40
65
70
75
80
90
95
20 40 60 80 10030 50 70 90
85
Efficiency [%]
Total Input Voltage [%]
18
75
70
65
60
80
85
90
30 36 48 66 7524 42 6054 72
RP10-4805SEW
Notes:
Note8: This power module is not internally fused. An input line fuse must always be used.