Datasheet
PD-4
REV.: 3/2018 www.recom-power.com
DC/DC Converter
Specifications (measured at Ta = 25°C, nominal input voltage, full load otherwise noted)
RP10-A
Series
PROTECTION
Parameter Condition Value
Short Circuit Protection (SCP) continuous, automatic recovery
Over Voltage Protection (OVP) Zener Diode Clamp
3.3Vout
5Vout
12Vout
15Vout
24Vout
3.7 - 5.4VDC
6.3 - 7.4VDC
13.5 - 19.6VDC
18.3 - 22.0VDC
29.1 - 32.5VDC
Over Load Protection (OLP) Hiccup mode, 150% of rated Iout typ.
Isolation Voltage tested for 1 minute
I/P to O/P
I/P (O/P) to case
1.6kVDC
1.0kVDC
Isolation Resistance tested with 500VDC 1GΩ min.
Isolation Capacitance 1500pF max.
Trim up 1 2 3 4 5 6 7 8 9 10 %
Vout = 24.24 24.48 24.72 24.96 25.20 25.44 25.68 25.92 26.16 26.40 Volts
R
U
= 570.333 278.667 181.444 132.833 13.667 84.222 70.333 59.917 51.815 45.333 kOhms
Trim up 11 12 13 14 15 16 17 18 19 20 %
Vout = 26.64 26.88 27.12 27.36 27.60 27.84 28.08 28.32 28.56 28.80 Volts
R
U
= 40.030 35.611 31.872 28.667 25.889 23.458 21.314 19.407 17.702 16.167 kOhms
Trim down 1 2 3 4 5 6 7 8 9 10 %
Vout = 23.76 23.52 23.28 23.04 22.80 22.56 22.32 22.08 21.84 21.60 Volts
R
D
= 4947.667 2439.333 1603.222 1185.167 934.333 767.111 647.667 558.083 488.407 432.667 kOhms
RP10-xx24SA
Notes:
Note6: This power module is not internally fused. An input line fuse must always be used. Recom suggests:
12Vin= T2A; 24Vin= T1A; 48Vin= T0.5A slow blow types
REGULATION
Parameter Condition Value
Output Voltage Accuracy ±1.0%
Line Voltage Regulation
low line to high line
Single
Dual
±0.2%
±0.5%
Load Voltage Regulation
0% to 100% load
Single
Dual
±0.2%
±1.0%
10% to 90% load
Single
Dual
±0.1%
±0.8%
Cross Regulation asymmetrical 25%<>100% load ±5.0%
Transient Response 25% load step change recovery time 250µs typ.