Datasheet

ROL
Package Style and Pinning (mm)
2.54
2.54
Top View
Bottom View
6.00
1.27
0.25
7.62
1.9
2134
4.10
0.51 typ.
0.51 typ.
10.00
RECOM
ROL-0505S
****
1.00
ø
+0.15/0
11.50
RECOM
ROL-0505S
****
Recommended Footprint Details
4 PIN SIP Package
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
ROL Pin Connections
Pin # Single
1 –Vin
2 +Vin
3 –Vout
4 +Vout
Typical Characteristics
ROL
Series
ECONOLINE
DC/DC-Converter
Efficiency %
100
0
40%0% 100%
40
Efficiency / Load
60%
80%
20%
20
60
80
Total Output current (%)
Deviation / Load
-10.000
40%0% 100%
Deviation from Nominal (%)
60%
80%
20%
-5.000
Total Output current (%)
0.000
5.000
10.000
15.000
20.000
25.000
Efficiency %
100
0
40%0% 100%
40
Efficiency / Load
60%
80%
20%
20
60
80
Total Output current (%)
Deviation / Load
-10.000
40%0% 100%
Deviation from Nominal (%)
60%
80%
20%
-5.000
Total Output current (%)
0.000
5.000
10.000
15.000
20.000
25.000
ROL-0505S
ROL-0515S
Notes
Note 1 Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter.
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
REV: 0/2015 E-7www.recom-power.com