Datasheet

www.recom-power.com
REV.: 2/2018 ECO-3
DC/DC Converter
Specifications (measured at Ta= 25°C, nominal input voltage, full load, otherwise noted)
RKE/H
Series
SAFETY AND CERTIFICATIONS
Certificate Type Report / File Number Standard
IEC/EN General Safety LVD1602031 IEC/EN60950-1, 2nd Edition, 2013
UL General Safety
E358085-A4
UL60950-1, 2nd Edition, 2007
CAN/CSA General Safety CSA C22.2 No. 60950-1, 2nd Edition, 2007
EAC RU-AT.49.09571 TP TC 004/2011
RoHs 2
2011/65/EU
EMC Compliance Condition Standard / Criterion
Electromagnetic compatibility of multimedia equip-
ment - Emission requirements
with external filter EN55032, Class B
continued on next page
PROTECTIONS
Parameter Condition Value
Isolation Voltage
(3)
I/P to O/P
tested for 1 second
tested for 1 minute
4kVDC
3kVDC
Isolation Capacitance 75pF max.
Isolation Resistance 1G min.
ENVIRONMENTAL
Parameter Condition
Value
Operating Temperature Range with derating -40°C to +85°C
Maximum Case Temperature +105°C
Operating Humidity non-condensing 5% to 95% RH
Vibration MIL-STD-202G
MTBF according to MIL-HDBK-217F, G.B.
+25°C
+85°C
13200 x 10³hrs
5200 x 10
3
hrs
Derating Graph
-40 -20 0 20 40 7060-30 -10 10 30 50 80 90
85
110100
100
80
60
40
90
70
50
30
20
10
0
Output Load [%]
Ambient Temperature [°C]
Notes: