Datasheet
RK_RH
www.recom-international.com
E-37
REV: 1/2013
Typical Characteristics
RK_RH
Series
ECONOLINE
DC/DC-Converter
Efficiency %
100
0
40%0% 100%
40
Efficiency / Load
60%
80%
20%
20
60
80
Total Output current (%)
3.312
1212
0512
Efficiency %
100
0
40%0% 100%
40
Efficiency / Load
60%
80%
20%
20
60
80
Total Output current (%)
0515
3.315
1215
Deviation / Load
-10.000
40%0% 100%
Deviation from Nominal (%)
60%
80%
20%
-5.000
Total Output current (%)
0512
0.000
5.000
10.000
15.000
20.000
25.000
3.312
1212
Deviation / Load
-10.000
40%0% 100%
Deviation from Nominal (%)
60%
80%
20%
-5.000
Total Output current (%)
0515
0.000
5.000
10.000
15.000
20.000
25.000
3.315
1215
Package Style and Pinning (mm)
2.54
1.00
ø
+0.15/0
2.54
Top View
0.51 typ.
2.54
1.00
ø
+0.15/0
2.54
Top View
Bottom View
Bottom View
( Suffix H )
( Suffix H )
( Suffix H )
for RH-types
for RH-types
7.05
6.00
RECOM
RK-xxxxS
****
12
5
7
19.60
0.51 typ.
4.10
10.20
1.27
0.25
15.24
2.0
19.65
1.27
0.25
15.24
2.0
RECOM
RK-xxxxS
****
RECOM
RH-xxxxD
****
12
5
7
6
RECOM
RK-xx1509D
1217
12
5
7
6
3rd angle
projection
Pin Connections
RK-xxxxS
Pin # Single
1 +Vin
2 –Vin
5 –Vout
7 +Vout
Recommended Footprint Details
Recommended Footprint Details
7 PIN SIP Package
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
Pin Connections
RH-xxxxD
Pin # Dual
1 +Vin
2 –Vin
5 –Vout
6 Com
7 +Vout
RH-xx12D
RH-xx15D
Notes
Note 1 Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter.
Certifications
EN General Safety Report: SPCLVD1109103 EN60950-1: 2006 + A12:2011
EN Medical Safety Report: SPCMDD1205098-4 IEC/EN 60601-1: 2006, 3rd Edition
UL General Safety Report: E358085 UL60950-1, 2nd Edtition
Isolated
DC/DC
Converter
IGBT
Driver
IGBT
Rg
+Vout
-Vout
Control Signal
-Vin
C1
C2
C3
+
+
+
1
2
7
6
5
IGBT Application
Circuit