Datasheet
www.recom-power.com
REV.: 4/2019 ECO-3
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RK/H6 & RH/H6
Series
ENVIRONMENTAL
Parameter Condition
Value
Operating Temperature Range without derating @ free air convection (see graph) -40°C to +90°C
Operating Altitude 5000m
Operating Humidity non-condensing 5% - 95% RH max.
MTBF according to MIL-HDBK-217F; G.B.
+25°C
+85°C
14919 x 10³ hours
9468 x 10³ hours
Derating Graph
SAFETY AND CERTIFICATIONS
Certificate Type Report / File Number Standard
Information Technology Equipment - General Requirements for Safety
E224736-A25-UL
UL60950-1, 2nd Edition, 2014
CAN/CSA-C22.2 No. 60950-1-07, 2nd Edtition, 2014
Audio/Video, information and communication technology equipment -
Part1: Safety requirements
UL62368-1, 2nd Edition, 2014
CAN/CSA-C22.2 No. 62368-1-14, 2nd Edtition, 2014
Information Technology Equipment, General Requirements for Safety (CB)
E224736-A26-CB-1
IEC60950-1:2005, 2nd Edition + A2:2013
Information Technology Equipment, General Requirements for Safety EN60950-1:2006 + A2:2013
Audio/video, information and communication technology equipment Part
1: safety requirements (CB)
OFF-4787079973-A-2
IEC62368-1:2014, 2nd Edition
Audio/video, information and communication technology equipment Part
1: safety requirements
EN62368-1:2014
continued on next page
-40 -20 0 20 40 7060-30 -10 10 30 50 80 90
95
110100
100
80
60
40
90
70
50
30
20
10
0
Output Load [%]
Ambient Temperature [°C]
PROTECTIONS
Parameter Condition Value
Short Circuit Protection (SCP) continuous
Isolation Voltage
(4)
I/P to O/P
tested for 1 second
rated for 1 minute
6.4kVDC
5.2kVDC
Isolation Resistance 10GΩ min.
Isolation Capacitance 75pF max.
Insulation Grade functional
Notes:
Note4: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Note5: Refer to local safety regulations if input over-current protection is also required. Recommended fuse: slow blow type