Datasheet

www.recom-power.com
REV.: 3/2019 ECO-3
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RI3
Series
REGULATIONS
Parameter Condition Values
Output Accuracy
5Vout
all other
±3.0% min. / ±4.0% typ.
±2.0% min. / ±3.0% typ.
Line Regulation low line to high line ±1.2% of 1.0% Vin typ.
Load Regulation
(4)
10% to 100% load
5Vout
all other
±8.0% typ. / ±10.0% max.
±6.0% typ. / ±10.0% max.
RI3-xx05S
RI3-xx12S
RI3-xx09S
RI3-xx15S
PROTECTIONS
Parameter Condition Value
Isolation Voltage tested for 1 second
standard without suffix
with suffix “/H2”
with suffix “/H3”
1kVDC
2kVDC
3kVDC
Isolation Capacitance 37pF typ. / 130pF max.
Isolation Resistance 10G min.
30
20
10
0
25
15
5
-5
-10
Deviation [%]
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
0509
1209
1509
2409
30
20
10
0
25
15
5
-5
-10
Deviation [%]
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
0515
1215
1515
2415
30
20
10
0
25
15
5
-5
-10
Deviation [%]
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
0505
1205
1505
2405
30
20
10
0
25
15
5
-5
-10
Deviation [%]
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
0512
1212
1512
2412
Deviation vs. Load
Notes:
Note4: Operation below 10% load will not harm the converter, but specifications may not be met