Datasheet

www.recom-power.com
REV.: 1/2018 ECO-3
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin and full load unless otherwise stated)
RI
Series
REGULATIONS
Parameter Condition Value
Output Accuracy ±5.0% max.
Line Regulation low line to high line, full load ±1.2% of 1.0% Vin typ.
Load Regulation 10% to 100% load
5Vout
12, 15Vout
15.0% max.
10.0% max.
Deviation vs. Load
25
15
5
-5
20
10
0
-10
Deviation [%]
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
0505
1205
2405
25
15
5
-5
20
10
0
-10
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
Deviation [%]
0515
1215
2415
25
15
5
-5
20
10
0
-10
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
Deviation [%]
0512
1212
2412
PROTECTIONS
Parameter Type Value
Short Circuit Protection (SCP)
without suffix
with suffix “/P”
1 second
continuous
Isolation Voltage
(5)
I/P to O/P
tested for 1 second
tested for 1 minute
1kVDC
500VAC/60Hz
Isolation Resistance 10G min.
Isolation Capacitance 30pF min./ 85pF max.
Insulation Grade basic
RI-xx05S
RI-xx15S
RI-xx12S
Notes:
Note5: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Note6: Refer to local wiring regulations if input over-current protection is also required. Recommended fuse: T2A slow blow type