Datasheet
www.recom-power.com
REV.: 0/2019 ECO-5
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RHV2
Series
Component List Class B
nom. Input Voltage C
1
L
1
5VDC, 12VDC, 24VDC 10µF, 50VDC MLCC 18µH choke RLS-226
+V
in
-V
in
+V
out
-V
out
-V
in
+V
in
C
1
L
1
-V
out
+V
out
+V
in
-V
in
+V
out
-V
out
-V
in
+V
in
C
1
L
1
-V
out
+V
out
Com
Com
EMC Filtering Suggestions according to EN55032
Single Output Dual Output
DIMENSION AND PHYSICAL CHARACTERISTICS
Parameter Type Value
Material
case
PCB
potting
black plastic, (UL94V-0)
FR4, (UL94V-0)
epoxy, (UL94V-0)
Package Dimension (LxWxH) 45.0 x 15.0 x 17.0mm
Weight 19.7g typ.
2.54
2.54
1 2
14 1615
embossed logo
Bottom View
0.25
±0.10
0.5
±0.10
45.0
12 x 2.54 = 30.48
15.0
5.00 17.0
Top View
1.50
Marking
3.45
0.50
1 2
14 1615
Pinning Information
Pin # Single Dual
1 +Vin +Vin
2 -Vin -Vin
14 -Vout -Vout
15 no pin Com
16 +Vout +Vout
Tolerance: xx.x= ±0.5mm
xx.xx= ±0.25mm
Recommended Footprint Details
Dimension Drawing (mm)
PACKAGING INFORMATION
Parameter Type Value
Packaging Dimension (LxWxH) tube 520.0 x 26.9 x 17.9mm
Packaging Quantity 10pcs
Storage Temperature Range -55°C to +125°C
Storage Humidity non-condensing 5% - 95% RH max.
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer.
The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or
cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the
unauthorized
use of RECOM products in such safety-critical applications.
Preliminary