Datasheet
www.recom-power.com
REV.: 0/2019 ECO-3
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RHV2
Series
REGULATIONS
Parameter Condition Value
Output Accuracy ±5.0% max.
Line Regulation low line to high line, full load ±1.2% of 1.0% Vin typ.
Load Regulation
(4)
10% to 100% load
12Vout, 24Vout
5Vout
10.0% max.
15.0% max.
Cross Regulation 10% to 100% load ±7.5% typ.
Notes:
Note4: Operation below 10% load will not harm the converter, but specifications may not be met
+10%
+5.5%
Vnom
+5%
-1%
-5%
Output Voltage [%]
10 50 100
Output Load [%]
Typical Load Line
+10%
+6%
Vnom
+5%
-3%
-5%
Output Voltage [%]
10 50 100
Output Load [%]
Typical Load Line
+10%
+4%
Vnom
+5%
-0.5%
-5%
Output Voltage [%]
10 50 100
Output Load [%]
Typical Load Line
+10%
+4%
Vnom
+5%
-1%
-5%
Output Voltage [%]
10 50 100
Output Load [%]
Typical Load Line
Tolerance Envelope
RHV2-0524S/R20
RHV2-2424S/R20
RHV2-2412D/R20RHV2-1212D/R20
PROTECTIONS
Parameter Type Value
Isolation Voltage
(5)
I/P to O/P
tested for 1 second
tested for 1 minute
20kVDC
12.5kVAC
Isolation Resistance 15GW min.
Isolation Capacitance
3.5pF typ./ 4pF max.
Insulation Grade reinforced
Notes:
Note5: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Note6: Refer to local safety regulations if input over-current protection is also required. Recommended fuse: slow blow type
Preliminary