Datasheet

www.recom-power.com
REV.: 11/2019 MED-3
DC/DC Converter
Specifications (measured @ Ta= 25°C, nominal input voltage, full load and after warm-up)
REM6
Series
PROTECTIONS
Parameter Condition Type Value
Short Circuit Protection (SCP) continuous, auto-recovery
Over Load Protection (OLP) % of Iout rated Hiccup mode, 150% typ.
Output Over Voltage Protection (OVP)
3.3Vout
5Vout
Single 12Vout
15Vout
24Vout
3.7VDC min. / 5VDC max.
5.6VDC min. / 7VDC max.
13.5VDC min. / 16VDC max.
18.3VDC min. / 22VDC max.
29.1VDC min. / 34.5VDC max.
5Vout
Dual 12Vout
15Vout
5.6VDC min. / 7VDC max.
13.5VDC min. / 18.2VDC max.
17VDC min. / 22VDC max.
Isolation Voltage I/P to O/P
working voltage
5kVAC / 1 minute
250VAC / continuous
Isolation Capacitance 12pF typ. / 17pF max.
Leakage Current 240VAC, 60Hz 2µA
Insulation Grade reinforced
Means of Protection 2MOPP
Medical Device Classification built-in power supply
Internal Clearance and Creepage I/P to O/P 8mm
External Clearance and Creepage I/P to O/P
“C” Pinning
“A” Pinning
>19.72mm
>14.64mm
Notes:
Note5: This Power module is not internally fused. A input line fuse must be always used
Recomended Fuse:
2:1 Input Voltage Fuse (slow blow)
5V T2.5A
12V T1.25A
24V T0.63A
48V T0.315A
4:1 Input Voltage Fuse (slow blow)
24V T1.25A
48V T0.63A
ENVIRONMENTAL
Parameter Condition
Value
Maximum Case Temperature Range
Maximum Ambient Temperature Range
-40°C to +105°C
see “Thermal Calculation” below
Temperature Coefficient 0.02%/K typ.
Thermal Impedance natural convection 0.1m/s 18K/W
Operating Altitude 5000m
Operating Humidity non-condensing 5% - 95% RH max.
Pollution Degree PD2
MTBF according to MIL-HDBK-217F, G.B. +25°C 4718 x 10
3
hours
Thermal Shock according to MIL-STD-810F standard
Vibration according to MIL-STD-810F standard
continued on next page