Datasheet

www.recom-power.com
REV.: 11/2019 MED-2
DC/DC Converter
Specifications (measured @ Ta= 25°C, nominal input voltage, full load and after warm-up)
REM6
Series
BASIC CHARACTERISTICS
Parameter Condition Min. Typ. Max.
Absolute Maximum Input Voltage
( 3sec max.)
2:1 input
5Vin nom.
12Vin nom.
24Vin nom.
48Vin nom.
16VDC
25VDC
50VDC
100VDC
4:1 input
24Vin nom.
48Vin nom.
50VDC
100VDC
Under Voltage Lockout
2:1 input
5Vin nom.
12Vin nom.
24Vin nom.
48Vin nom.
4VDC
8VDC
16VDC
33VDC
4.5VDC
9VDC
18VDC
36VDC
4:1 input
24Vin nom.
48Vin nom.
8VDC
16VDC
9VDC
18VDC
Start-up Time constant resistive load, Power up or Remote ON/OFF 30ms
Remote ON/OFF
(referenced to -Vin Pin)
DC-DC ON
DC-DC OFF
Open or 0-1.2VDC
2.2-12VDC
Current of CTRL Pin -0.5mA 1mA
Remote OFF Input Current 2.5mA
Internal Operating Frequency 225kHz 250kHz 275kHz
Output Ripple and Noise
(20MHz BW limited)
10µF/25V X7R MLCC for 3.3, 5Vout
10µF/25V X7R MLCC for 12, 15Vout
4.7µF/50V X7R MLCC for 24Vout
30mVp-p
40mVp-p
50mVp-p
REGULATIONS
Parameter
Condition
Type
Value
Output Accuracy ±1.0%
Line Regulation low line to high line
Single
Dual
±0.2%
±0.5%
Load Regulation no load to full load
Single
Dual
0.2%
1.0%
Cross Regulation asymmetrical load 25% / Full Load only Dual Output ±5.0%
Transient Response 25% load step change 250µs
10 20 30 40 50 60 70 80 90 100
Load [%]
50
40
30
20
10
0
60
70
80
90
100
Efficiency [%]
Efficiency vs. Load
REM6-1212D