Datasheet

DC/DC Converter
www.recom-power.com
REV.: 1/2019 MED-8
Specifications (measured @ Ta= 25°C, nominal input voltage. full load and after warm-up)
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.
PACKAGING INFORMATION
Parameter Type Value
Packaging Dimension (LxWxH) tube 290.0 x 43.5 x 19.7mm
Packaging Quantity 10 pcs
Storage Temperature Range -55°C to +125°C
Stoarge Humidity non-condensing 5% to 95% RH max.
Dimension Drawing (mm)
Bottom View
40.6
tc
10.2
Ø1.0
±0.1
2.54
Top View
25.4
5.6
±0.25
14 x 2.54= 35.56
5.0810.16
5.10
2.542.5410.16
2.54
1
1
1
2
2
(3)
(3)
6
6
5 5
4
4
Recommended Footprint Details
Pin Connections with suffix /P
Pin # Single Dual
1 +Vin +Vin
2 -Vin -Vin
3 CTRL CTRL
4 Trim -Vout
5 -Vout Com
6 +Vout +Vout
Tolerance: xx.x= ±0.5mm
xx.xx= ±0.25mm
Pin Connections without suffix /P
Pin # Single Dual
1 +Vin +Vin
2 -Vin -Vin
4 Trim -Vout
5 -Vout Com
6 +Vout +Vout
Tolerance: xx.x= ±0.5mm
xx.xx= ±0.25mm
REM20-W
Series