Datasheet
www.recom-power.com
REV.: 5/2018 MED-5
DC/DC Converter
Specifi cations (measured @ Ta= 25°C, nominal input voltage, full load and after warm-up)
REM1
Series
EMC Filtering Suggestions according to EN55011
Component List Class B
C1
C2
+V
in
-V
in
+V
out
-V
out
+V
in
-V
in
+V
out
-V
out
L1
Input Voltage C1 C2 L1
3.3VDC
4.7µF
470pF/6kVDC
22µH Choke
5VDC
12VDC
15VDC
24VDC 2.2µF 47µH Choke
DIMENSION and PHYSICAL CHARACTERISTICS
Parameter Type Value
Material
case
potting
PCB
black plastic, (UL94 V-0)
silicone (UL94 V-0)
FR4 (UL94 V-0)
Dimension (LxWxH) 19.6 x 6.0 x 10.2mm
Weight 2.6g typ.
Pin Connections
Pin # Single
1 +Vin
2 -Vin
6 -Vout
7 +Vout
Tolerance: xx.x= ±0.5mm
xx.xx= ±0.25mm
Pin dimension: ±0.1mm
Dimension Drawing (mm)
PACKAGING INFORMATION
Parameter Type Value
Packaging Dimension (LxWxH) tube 520.0 x 16.0 x 9.3mm
Packaging Quantity 25pcs
Storage Temperature Range -55°C to +125°C
Storage Humidtiy non-condensing 95% RH max.
Bottom View
Top View
0.50
1.27
10.2
0.51
6.0
1.00 Ø
+0.15/-0
19.6
6x2.54= 15.242.0
2.54
2.54
4.1
0.25
1 2 6 7
1 2 6 7
Marking
embossed logo
Recommended Footprint Detail
The
product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer.
The
products
are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or
cause
loss
of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the
unauthorized
use of RECOM products in such safety-critical applications.