Datasheet
REC8
Derating-Graph
(Ambient Temperature)
Output Power (%)
100
60
20
40
100
500-40
71
150
Operating Temperature °C
0
80
Safe Operating Area
4:1
Specifications cont. (measured at T
A
= 25°C, nominal input voltage, full load and after warm-up)
Input Surge Voltage (100ms max.) 5V Input 15VDC
12V Input 36VDC
24V Input 50VDC
48V Input 100VDC
Isolation Voltage H2-Suffix and SMD (tested for 1 second) 2000VDC
(rated for 1 minute**) 1000VAC / 60Hz
H3-Suffix (tested for 1 second) 3000VDC
(rated for 1 minute**) 1500VAC / 60Hz
Isolation Capacitance 1200pF typ.
Isolation Resistance 1 GΩ min.
Overload Protection 150% typ.
Short Circuit Protection Continuous, Auto Restart
Operating Temperature Range 4:1 -40°C to +71°C (see Graph)
2:1- Vin=5V -40°C to +71°C (see Graph)
(free air convection) 2:1 - All Others -40°C to +85°C (see Graph)
Remote On/Off DC/DC ON Open or 3.5V<Vr<12V
DC/DC OFF Short or 0V<Vr<1.2V
Storage Temperature Range -55°C to +105°C
Temperature Coefficient ±0.05% max.
Relative Humidity 95% RH max.
Case Material Nickel Plated Metal with Non-Conductive Base
Thermal Impedance Natural convection 12°C/W
Maximum Case Temperature 100°C
Vibration 10-55Hz, 2G, 30mins along X,Y & Z
Package Weight 18g
Packing Quantity Tube 15 pcs
Tape and Reel 100 pcs
MTBF (+25°C) using MIL-HDBK 217F 1200 x 10
3
hours
(+71°C) using MIL-HDBK 217F >300 x 10
3
hours
Certifications
EN General Safety Report: SPCLVD1211033-2 EN60950-1:2006 +A12:2011
UL General Safety Report: E224736 UL 60950-1 1st Ed.
C22.2 No. 60950-1-03
EN Medical Safety Report: MDD12060585 + RM1206085 IEC/EN 60601-1 3rd Edition
Medical Report + ISO14971 Risk Assessment
REC8-S_DRW(Z)/H*/A/M
Series
ECONOLINE
DC/DC-Converter
Detailed Information see
Application Notes chapter "MTBF"
}
Output Power (%)
100
60
20
40
100
500-40
85
150
Operating Temperature °C
0
80
Safe Operating Area
71
2:1 Vin =5V
2:1 - All Others
2:1 Converters
4:1 Converters
Note: Refer to Application Notes for EMC Class B Filter suggestion
**Any data referred to in this datasheet are of indicative
nature and based on our practical experience only.
For further details, please refer to our Application Notes.
Typical Characteristics
Efficiency %
100
0
40%0% 100%
40
Efficiency / Load (Nominal Vin)
60%
80%
20%
20
60
80
Total Output current (%)
1205S
1212S
REC8-1205SRW/H2/A/M (/SMD)
REC8-1212SRW/H2/A/M (/SMD)
9
Efficiency VS Input Voltage
70
72
74
76
78
80
82
84
86
88
90
Efficiency (%)
Input Voltage (V)
1205
1212
18
12
14
1610