Datasheet
REC6/R
Input Voltage Range 2:1
Output Voltage Accuracy ±2% max.
Line Regulation (HL-LL) ±0.3% max.
Load Regulation (for output load current change from 20% to 100%) ±0.6% max.
Input Surge (1 minute) 5V types 16V max.
12V types 25V max.
24V types 50V max.
48V types 100V max.
Undervoltage Lockout (/X1 Versions) 5V types 3.5V typ. (±20%)
12V types 7V typ. (±20%)
24V types 15V typ. (±10%)
48V types 32V typ. (±10%)
Output Ripple and Noise (0,1µF capacitor on output, 20MHz BW limited) 200mVp-p max.
Transient Response (25% step change) 1ms typ.
Switching Frequency (Full load and nominal input voltage) 100kHz min. / 350kHz max.
Input Filter Pi Network
Capacitors All types MLCC capacitors only
Minimum Load (Operation under no-load will not damage the converter, but it may not meet all specifications) 20% Full Load
No Load Power Consumption 400mW max.
Isolation Voltage R8-Suffix (tested for 1 second) 8000VDC
(rated for 1 minute**) 4000VAC / 60Hz
Isolation Voltage R10-Suffix (tested for 1 second) 10000VDC
(rated for 1 minute**) 5000VAC / 60Hz
Isolation Capacitance 20pF typ.
Isolation Resistance 10 GΩ min.
Short Circuit Protection (Max operating temp. = 50°C during short circuit conditions) Continuous, Auto Restart
Operating Temperature Range (free air convection) -40°C to +75°C (see Graph)
Case Temperature 105°C max.
Storage Temperature Range -55°C to +125°C
Relative Humidity 95% RH
Case Material Non-Conductive Plastic
Potting Material Silicone
Thermal Impedance Natural convection 20°C/W
Package Weight 14g
Packing Quantity 15 pcs per Tube
MTBF (+25°C) using MIL-HDBK 217F 953 x10
3
hours
(+75°C) using MIL-HDBK 217F 234 x10
3
hours
EMC Conducted Emissions EN55022 Class A
(with 470µF//0.1µF capacitors across input) Radiated Emissions EN55022 Class A
Reinforced Isolation Transformer Creepage /R8 and /R10 Types 4.6 mm min.
Transformer Clearance /R8 and /R10 Types 2.4 mm min.
PCB Creepage & Clearance /R8 and /R10 Types 6.0 mm min.
Optocoupler Creepage /R8 and /R10 Types 6.0 mm min.
External Creepage and Clearance Plastic Case Input <> Output pins 14.2 mm min.
Certifications EN Medical Safety Report: MDD1207051 + RM1207051 EN 60601-1 3rd Edition
Medical Report + ISO14971 Risk Assessment
IEC Medical Safety CB-Report: CA-10168-A1-UL IEC60601-1 3rd Edition
CSA Medical Safety Report: 2202478 C22.2 601-1 2nd Ed.
UL Medical Safety E314885-A4 UL 60601-1 3rd Edition
General Safety Report: 2219431 C22.2 No. 60950-1-03
UL 60950-1 1st Ed. Recognised as Reinforced Isolation Supplement to Report: 2219431
Specifications (measured at T
A
= 25°C, nominal input voltage, full load and after warm-up)
REC6-S_DRW
/R* Series
ECONOLINE
DC/DC-Converter
}
Detailed Information see
Application Notes chapter "MTBF"
**Any data referred to in this datasheet are of indicative nature and based on our practical experience only. For further details, please refer to our Application Notes.
REV: 0/2015 www.recom-power.comE-154