Datasheet

ECONOLINE
DC/DC-Converter
with 3 year Warranty
REC6/R
Refer to Application Notes
8kVDC
&
10kVDC Reinforced Isolation
Industry Standard DIP24 Package
6W Regulated Output
Continuous Short Circuit Protection
Wide Input 2:1
Medical Approved
EN, CSA and CB Certificates
2 Pinout Options
Control Pin Option
Efficiency to 86%
Features
Regulated
Converters
6 Watt DIP24
Reinforced
Single
& Dual
Output
Selection Guide
Part Input Output Output Efficiency Max
Number Voltage Voltage Current Capacitive
DIP24 (VDC) (VDC) (mA) (%) Load
(1)
REC6-xx05SRW/R* 9 - 18, 18 - 36, 36 - 75 5 1000 80, 81, 82 6800µF
4.5 - 9 77
REC6-xx09SRW/R* 9 - 18, 18 - 36, 36 - 75 9 667 81, 82, 83 6800µF
4.5 - 9 555 80
REC6-xx12SRW/R* 9 - 18, 18 - 36, 36 - 75 12 500 82, 83, 84 6800µF
4.5 - 9 417 82
REC6-xx15SRW/R* 9 - 18, 18 - 36, 36 - 75 15 400 84, 85, 86 6800µF
4.5 - 9 333 83
REC6-xx24SRW/R* 9 - 18, 18 - 36, 36 - 75 24 250 83, 84, 85 4700µF
4.5 - 9 208 82
REC6-xx05DRW/R* 9 - 18, 18 - 36, 36 - 75 ±5 ±500 80, 81, 82 ±2200µF
4.5 - 9 77
REC6-xx09DRW/R* 9 - 18, 18 - 36, 36 - 75 ±9 ±335 81, 82, 83 ±2200µF
4.5 - 9 ±278 80
REC6-xx12DRW/R* 9 - 18, 18 - 36, 36 - 75 ±12 ±250 81, 82, 83 ±2200µF
4.5 - 9 ±208 82
REC6-xx15DRW/R* 9 - 18, 18 - 36, 36 - 75 ±15 ±200 82, 83, 84 ±2200µF
4.5 - 9 ±167 80
R* = R8 or R10 for 8kVDC or 10kVDC isolation.
Note 1: Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second
without damage to the converter.
The REC6 series uses a reinforced isolation transformer to offer exceptionally high isolation of
8kVDC (4kVAC/1 minute) or 10kVDC (5kVAC/1minute) making it suitable for HT monitoring cir-
cuits, mains power meters, IGBT isolated power supplies and other sophisticated industrial and
medical applications. The isolation capacitance of only 20pF makes them also suitable for low
leakage applications. The isolation transformer is recognized by CSA as reinforced isolated with
a minimum internal clearance of 2.4mm and a minimum internal creepage clearance of 4.6mm.
The REC6 is available in two industry-standard pinouts (= "/A" or "/C"). Remote on/off con-
trol is possible with the /CTRL option (A pinning only) and an optional undervoltage lockout
function is also available (="/X1"). The converters can deliver 140% rated power for short pe-
riods of time to cope with applications with large capacitive loads or high start up currents.
Description
2:1 Input
(REC6-S_DRW/R8(R10)
xx = 4.5-9Vin = 05
xx = 9-18Vin = 12
xx = 18-36Vin = 24
xx = 36-75Vin = 48
* add suffix "/A" or "/C" for pinning options, see next page for details.
* add suffix /CTRL for control pin option (A Pinning only)
* add suffix "/X1" for Undervoltage Lockout
Ordering Examples:
REC6-0512DRW/R8/A/CTRL= 5V Vin, ±12V Vout, 8kVDC isolation, pinout “A”,control pin
REC6-4805SRW/R10/A = 48V Vin, 5V Vout, 10kVDC isolation, pinout “A
REC6-1212DRW/R8/C/X1 = 12V Vin, ±12V Vout, 8kVDC isolation, pinout “C”,UVL
REC6-0505SRW/R10/A/CTRL/X1 = 5V Vin, 5V Vout, 10kVDC isolation, pinout “A”,control pin, UVL
Derating-Graph
(Ambient Temperature)
Output Power (%)
120
100
20
60
125
75
0
-40
Operating Temperature (°C)
0
80
5025
85
40
105
Safe Operating Area
C22.2-No. 60950 Certified
C22.2-601.1 Certified
UL-60601.1 Certified
E-314885
RoHS
2011/65/EU
6/6
REV: 0/2015 E-153www.recom-power.com

Summary of content (4 pages)