Datasheet
www.recom-power.com
REV.: 5/2018 ECO-2
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin and full load unless otherwise stated)
REC5A
Series
REGULATIONS
Parameter Condition Values
Output Accuracy
±2.0% typ.
Line Regulation low line to high line ±0.3% max.
Load Regulation 0% to 100% load 0.6% max.
Deviation vs. Load
Efficiency vs. Load
REC5A-0505SW/H2
REC5A-0505SW/H2
REC5A-2405SW/H2
REC5A-2405SW/H2
PROTECTIONS
Parameter Condition Value
Short Circuit Protection (SCP) below 100mΩ continuous, automatic recovery
Over Load Protection (OLP) 120% min., 140% typ.
Isolation Voltage
(4)
tested for 1s 2kVDC
Isolation Resistance 1GΩ min.
Isolation Capacitance 2200pF max.
Insulation Grade functional
Notes:
Note4: For repeat Hi-Pot testing, reduce the ime and/or the test voltage
0 10 20 30 40 50 60 70 80 90
100
100
80
60
40
90
70
50
30
20
10
0
Efficiency [%]
Output Load [%]
4.5Vin
7Vin
9Vin
Deviation [%]
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
0
0.05
0.15
0.25
0.3
0.35
0.4
0.45
0.1
0.2
4.5Vin
7Vin
9Vin
0 10 20 30 40 50 60 70 80 90
100
100
80
60
40
90
70
50
30
20
10
0
Efficiency [%]
Output Load [%]
18Vin
24Vin
36Vin
Deviation [%]
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
0
0.1
0.2
0.3
0.4
0.5
0.6
18Vin
24Vin