Datasheet

Input Voltage Range 2:1 & 4:1
Output Voltage Accuracy ±2% max.
Line Regulation (HL-LL) ±0.3% max.
Load Regulation (for output load current change from 20% to 100%) ±0.6% max.
Minimum Load 10%
(2)
Output Ripple and Noise (0,1µF capacitor on output, 20MHz BW) 50mVp-p max.
Operating Frequency at Full Load 2:1 input 120kHz typ.
(at nominal input voltage) 4:1 input 200kHz typ.
Input Filter Pi Network
Efficiency at Full Load see above
No Load Power Consumption 300mW max.
Isolation Voltage H2-Suffix (tested for 1 second) 2000VDC
(rated for 1 minute**) 1000VAC / 60Hz
Isolation Voltage H4-Suffix (tested for 1 second) 4000VDC
(rated for 1 minute**) 2000VAC / 60Hz
Isolation Voltage H6-Suffix (tested for 1 second) 6000VDC
(rated for 1 minute**) 3000VAC / 60Hz
Isolation Capacitance 60pF typ.
Isolation Resistance 1 GΩ min.
Short Circuit Protection (Max temp. = 50°C during short circuit conditions) Continuous, Auto Restart
Operating Temperature (free air convection) -40°C to +75°C (see Graph)
Storage Temperature Range -55°C to +125°C
Relative Humidity 95% RH
Case Material Non-Conductive Plastic or Metal
Thermal Impedance Natural convection 20°C/W for plastic case
12°C/W for metal case
Package Weight 13g
Packing Quantity 15 pcs per Tube
100 pcs per Reel
MTBF (+25°C) using MIL-HDBK 217F 850 x 10
3
hours
(+75°C) using MIL-HDBK 217F 206 x 10
3
hours
Certifications
UL General Safety Report: E358085 UL 60950-1 1st Ed.
C22.2 No. 60950-1-03
EN General Safety Report: SPCLVD1212007 EN60950-1:2006 + 9+A1:2010+A12:2011
EN Medical Safety Report: MDD1205098-3 + RM1205098-3
IEC/EN 60601-1 3rd Edition, Medical Report + ISO14971 Risk Assessment
REC 5
Specifications (measured at T
A
= 25°C, nominal input voltage, full load and after warm-up)
REC5-S_DRW(Z)
/H* Series
ECONOLINE
DC/DC-Converter
Typical Characteristics
Efficiency %
100
0
40%0% 100%
40
Efficiency / Load
60%
80%
20%
20
60
80
Total Output current (%)
1212
123.3
1209
1205
Efficiency %
100
0
40%0% 100%
40
Efficiency / Load
60%
80%
20%
20
60
80
Total Output current (%)
2412
243.3
2405
12V Single 2:1
24V Single 2:1
}
Detailed Information see
Application Notes chapter "MTBF"
Ordering Examples:
REC5-0512DRW/H2/A/CTRL= 2:1 input, 5V Vin,
±12V Vout, 2kVDC, pinout “A”,plastic case, control pin
REC5-4812SRWZ/H4/A/M = 4:1 input, 48V Vin, 12V
Vout, 4kVDC, pinout “A”,metal case, no control pin
REC5-1212DRWZ/H/B = 4:1 input, 12V Vin, ±12V
Vout, 1.6kVDC, pinout “B”,plastic case, no control pin
REC5-0505SRW/H6/C/SMD = 2:1 input, 5V Vin, 5V
Vout, 6kVDC, SMD pinout “C”,plastic case, no control
pin
**Any data referred to in this datasheet are of indicative nature and based on our practical experience only. For further details, please refer to our Application Notes.
Notes
Note 1: Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter.
Note 2: The REC 5 series requires a minimum of 10% load on the output to maintain specified regulation. Operating under no-load conditions
will not damage these devices; however, they may not meet all listed specifications.
‘B” Pinning is restricted to 1.6kV isolation due
to the closeness of the input and output pins.
If the options "/M" for metal case and "/SMD"
for SMD pinout are combined, the maximum
allowed isolation voltage is 2kVDC because of
the shorter distances between pins and the
metal case.
DIP-24 through-hole case and SMD-plastic
case are not affected and offer the full isolation
barriers of 2kV through to 6kVDC.
Isolation Restrictions
REV: 0/2015 www.recom-power.comE-150