Selection Guide
Part Input Output Output Efficiency Max
Number Voltage Voltage Current Capacitive
SIP 7 2kV (VDC) (VDC) (mA) (%) Load
(1)
RD-xx05D (H) 5, 12, 24 ±5 ±200 75-82 ±470µF
RD-xx12D (H) 5, 12, 24 ±12 ±84 80-84 ±330µF
RD-xx15D (H) 5, 12, 24 ±15 ±66 82-86 ±330µF
RD-xx24D (H) 5, 12, 24 ±24 ±42 82-86 ±100µF
xx = Input Voltage. Other input and output voltage combinations available on request.
* add Suffix “P” for Continuous Short Circuit Protection, e.g. RD-0505D/P, RD-0505D/HP
Output Power (%)
100
60
20
40
100500-40
85
150
Operating Temperature °C
0
80
Safe Operating Area
Input Voltage Range ±10%
Output Voltage Accuracy ±5%
Line Voltage Regulation 1.2%/1% of Vin typ.
Load Voltage Regulation 3.3V output types 20% max.
(10% to 100% full load) 5V output type 15% max.
9V, 12V, 15V, 24V output types 10% max.
Output Ripple and Noise (20MHz limited) 150mVp-p max.
Operating Frequency 34kHz min. / 50kHz typ. / 85kHz max.
Efficiency at Full Load 70% min. / 80% typ.
Minimum Load = 0% Specifications valid for 10% minimum load only.
Isolation Voltage (tested for 1 second) 1000VDC
(rated for 1 minute) 500VAC / 60Hz
Isolation Voltage H-Suffix (tested for 1 second) 2000VDC
H-Suffix (rated for 1 minute) 1000VAC / 60Hz
Isolation Capacitance 40pF min. / 115pF max.
Isolation Resistance 10 GΩ min.
Short Circuit Protection 1 Second
P-Suffix Continuous
Operating Temperature Range (free air convection) -40°C to +85°C (see Graph)
Storage Temperature Range -55°C to +125°C
Relative Humidity 95% RH
Package Weight 2.8g
Packing Quantity 25 pcs per Tube
MTBF (+25°C) using MIL-HDBK 217F 988 x 10
3
hours
(+85°C) using MIL-HDBK 217F 135 x 10
3
hours
2 Watt
SIP7
Dual Output
Derating-Graph
(Ambient Temperature)
●
Low Cost 2W Dual Output Converter
●
Industry Standard SIP7 and DIP14 Packages
●
Power Sharing on Outputs
●
Optional Continuous Short Circuit Protected
●
1kVDC and 2kVDC Isolation Options
●
UL94V-0 Package Material
●
Efficiency to 86%
Features
Unregulated
Converters
}
Detailed Information see
Application Notes chapter "MTBF"
The RD series have been specifically designed for applications where dual power rails need to be created from a single
rail supply and a low cost solution is required.
With efficiencies up to 85%, the full output power is available over the operating temperature range -40°C to +85°C and
the converters can be used in ambient temperatures of up to 100°C with derating.
The wide selection of industry standard input voltage and output voltage options plus an I/O-Isolation of 1kVDC or 2kVDC
makes these converters suitable for many industrial applications.
Description
Specifications (measured at T
A
= 25°C, nominal input voltage, full load and after warm-up)
Refer to Application Notes
RoHS
2011/65/EU
6/6