Datasheet
www.recom-power.com
REV.: 1/2018 ECO-4
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin und full load otherwise stated)
RBM
Series
Deviation vs. Load
25
15
5
-50
20
10
0
-10
Deviation [%]
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
3.315
0515
1215
25
15
5
-50
20
10
0
-10
Deviation [%]
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
3.312
0512
1212
25
15
5
-50
20
10
0
-10
Deviation [%]
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
3.305
0505
1205
25
15
5
-50
20
10
0
-10
Deviation [%]
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
3.315
0515
1215
PROTECTIONS
Parameter Type Value
Short Circuit Protection (SCP)
without suffix
with suffix “/P”
1 second
continuous
Isolation Voltage
(5)
I/P to O/P
tested for 1 second
rated for 1 minute
3kVDC
1.5kVAC/60Hz
Isolation Resistance 15GΩ min.
Isolation Capacitance 20pF min. / 65pF max.
Insulation Grade basic
Notes:
Note5: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Note6: Refer to local wiring regulations if input over-current protection is also required. Recommended fuse: T1A slow blow type
RBM-xx15S
RBM-xx05D
RBM-xx12D
RBM-xx15D