Datasheet

RB
Series
ECONOLINE
DC/DC-Converter
Efficiency %
100
0
40%0% 100%
40
Efficiency / Load
60%
80%
20%
20
60
80
Total Output current (%)
3.305
0505
1205
Efficiency %
100
0
40%0% 100%
40
Efficiency / Load
60%
80%
20%
20
60
80
Total Output current (%)
0509
1209
3.309
Efficiency %
100
0
40%0% 100%
40
Efficiency / Load
60%
80%
20%
20
60
80
Total Output current (%)
3.312
0512
1212
Deviation / Load
-10.000
40%0% 100%
Deviation from Nominal (%)
60%
80%
20%
-5.000
Total Output current (%)
0505
0.000
5.000
10.000
15.000
20.000
25.000
3.305
1205
Deviation / Load
-10.000
40%0% 100%
Deviation from Nominal (%)
60%
80%
20%
-5.000
Total Output current (%)
0509
0.000
5.000
10.000
15.000
20.000
25.000
3.309
1209
Deviation / Load
-10.000
40%0% 100%
Deviation from Nominal (%)
60%
80%
20%
-5.000
Total Output current (%)
0512
0.000
5.000
10.000
15.000
20.000
25.000
3.312
1212
Efficiency %
100
0
40%0% 100%
40
Efficiency / Load
60%
80%
20%
20
60
80
Total Output current (%)
3.315
1215
0515
Deviation / Load
-10.000
40%0% 100%
Deviation from Nominal (%)
60%
80%
20%
-5.000
Total Output current (%)
0515
0.000
5.000
10.000
15.000
20.000
25.000
3.315
1215
Typical Characteristics - Single Output
Specifications (measured at T
A
= 25°C, nominal input voltage, full load and after warm-up)
Package Weight 2.2g
Packing Quantity 25 pcs per Tube
MTBF (+25°C) using MIL-HDBK 217F 1012 x 10
3
hours
(+85°C) using MIL-HDBK 217F 151 x 10
3
hours
Certifications
CB Test Report Report: E22406 IEC 60950-1:2005 2nd Ed.
UL General Safety Report: E358085 UL 60950-1 2nd Ed.
EN General Safety Report: SPCLVD1109103 EN60950-1:2006 + A12:2011
EN Medical Safety Report: MDD1112018 + RM1112018 IEC/EN 60601-1 3rd
EditionMedical Report + ISO14971 Risk Assessment
RB-xx05S RB-xx09S
RB-xx12S RB-xx15S
}
Detailed Information see
Application Notes chapter "MTBF"
RB