Datasheet

RAM Series
ECONOLINE
DC/DC-Converter
Efficiency %
100
0
40%0% 100%
40
Efficiency / Load
60%
80%
20%
20
60
80
Total Output current (%)
1205
2405
0505
Deviation / Load
-10
40%0% 100%
Deviation from Nominal (%)
60%
80%
20%
-5
Total Output current (%)
0505
0
5
10
15
20
25
1205
2405
RAM-xx05S
Typical Characteristics
+10%
+5%
V Nom.
+5%
 1%
10% 50% 100%
Output Voltage
Output Load Current (%)
 5%
Typical Load Line
RAM
Tolerance Envelope
Package Style and Pinning
8.70
10.65
RECOM
RAM-xx05S
Pb
9.00
0.90
28 27 17 16 15
1 2 12 13 14
4.05 max.
1.27x13
18.00
6.70
TOP VIEW
1.27
13*1.27= 16.51
1.40
11.80
Pin Connections
Pin # Function
1 +Vin
2 -Vin
12 -Vout
13 +Vout
14~17 NC
27,28 NC
NC = No Connection
Unit: mm
Tolerance: ± 0.25 mm
+
Output
C1
Input
470pF/6kVDC
GND
DC
DC
GND
EMC Filtering - Suggestion for EN55022 Class B
Input Inductance/
Voltage Capacitance (C1)
5V 10µF
12V 4.7µF
24V 22µF
Notes
Note 1: Maximum capacitive load is defined as the capacitive load tha will allow start up in under 1 second without damage to the converter
Recommended Footprint Details
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
REV: 0/2015 E-63www.recom-power.com