Datasheet
www.recom-power.com
REV.: 2/2019 L-3
AC/DC Converter
Specifications (measured @ ta= 25°C and 115/230VAC)
RACD07
Series
SAFETY AND CERTIFICATIONS
Certificate Type (Safety) Report Number
Standard for LED Equipment for use in Lighting Products
E340696-1-7
UL8750, 1st Edition, 2012
Standard for Class 2 Power Units UL1310, 6th Edition, 2013
LED Equipment for Lighting Applications
CAN/CSA-C22.2 No. 250.13-12, 1st Edition, 2013
Safety of control gear for LED modules
PSE102-0283
IEC/EN61347-2-13, 2nd Edition, 2006
Safety requirements for lamp controlgear
IEC61347-1, 2nd Edition, 2010
EN61347-1, 2nd Edition, 2011
RoHS2 RoHS-2011/65/EU + AM-2015/863
EAC RU Д- AT.A Г03. В.67369 TP TC 004/020, 2011
EMC Compliance
Condition
Standard / Criterion
Limits and methods of measurement of radio disturbance characteristics of
electrical lighting and similar equipment
EN55015, Class B
Information technology equipment - Radio disturbance characteristics -
Limits and methods of measurement
CISPR22, 3rd Edition, 1997
Radio Frequency Devices, Subpart B - Unintentional Radiators CFR 47, Part 15, Class B
Methods of Measurement of Radio-Noise Emissions from Low-Voltage
Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
ANSI C63.4
Alternating Current High Voltage Power Systems Canadian ICES-004 issue 5, 2012
Limits for harmonic current emissions IEC61000-3-2, 2009
Limitation of voltage fluctuations/flicker in low-voltage systems IEC61000-3-3, 2008
ESD Electrostatic discharge immunity test
±8kV Air Discharge,
±4kV Contact Discharge
EN61547, 2009 / IEC61000-4-2, 2008
Radiated, radio-frequency, electromagnetic field immunity test 3V/m EN61547, 2009 / IEC61000-4-3, 2010
Fast Transient and Burst Immunity ±0.5kV / ±1kV (AC Input) EN61547, 2009 / IEC61000-4-4, 2012
Surge Immunity ±0.5kV (AC Input) EN61547, 2009 / IEC61000-4-5, 2005
Immunity to conducted disturbances, induced by radio-frequency fields
3kV
EN61547, 2009 / IEC61000-4-6, 2008
Power Frequency Magnetic Field Immunity 3A/m at 50/60Hz EN61547, 2009 / IEC61000-4-8, 2009
Voltage Short Interruptions 100% reduction, 10ms EN61547, 2009 / IEC61000-4-11, 2004
Voltage Dips 30% reduction, 200ms EN61547, 2009 / IEC61000-4-11, 2004
Derating Graph
(@ natural air convection 0.1m/s)
-20 -10 0 10 20 30 40 50 60
100
80
60
40
90
70
50
30
20
10
0
Output Load [%]
Ambient Temperature [°C]