Datasheet

www.recom-power.com
REV.: 2/2019 L-2
AC/DC Converter
Specifications (measured @ ta= 25°C and 115/230VAC)
RACD07
Series
PROTECTION
Parameter Condition Value
Internal Input Fuse T1A, slow blow
Short Circuit Protection (SCP)
Hiccup Mode, autorecovery after fault condition is removed
Overload Protection (OLP)
105% - 120% typ.
Over Current Protection (OCP) Constant current mode protection
Isolation Voltage I/P to O/P 3.75kVAC / 1 minute
Isolation Resistance 500VDC 100MW min.
Maximum loading of automatic circuit breakers*
Circuit Breaker Circuit Breaker Current
Typ 10A 16A 20A 25A
C 101 128 171 228
Circuit Breaker Circuit Breaker Current
Typ 10A 16A 20A 25A
B 61 100 121 150
C 121 164 221 291
Circuit Breaker Circuit Breaker Current
Typ 10A 16A 20A 25A
B 70 115 139 172
C 139 188 254 334
* @ 115VAC, 1Ohm, 90° phase angle
and max. load
* @ 230VAC, 1Ohm, 90° phase angle
and max. load
* @ 277VAC, 1Ohm, 90° phase angle
and max. load
REGULATIONS
Parameter Condition Value
Output Voltage Accuracy includes: line, load and tolerance ±5%
Output Current Accuracy ±3% typ. / ±7% max.
ENVIRONMENTAL
Parameter Condition
Value
Operating Temperature Range @ natural convection 0.1m/s, full load -20°C to +50°C
Max. Case Temperature k +65°C
Operating Humidity non condensing 20% - 90% RH
IP Rating IP67
Vibration 10-500Hz, 2G; 10 minute/cycle 1 cycle period for 60 min each along X, Y and Z axes
Design Lifetime +25°C ambient 70 x 10
3
hours
MTBF
according to MIL-HDBK-217F,
G.B. +25°C 200 x 10³ hours
continued on next page
Input Voltage vs. Load
Notes:
Note3: Refer to local wiring regulations if input over-current protection is also required
100
80
60
40
90
70
50
30
20
10
0
Output Load [%]
Input Voltage [VAC]
80 90 100 120 140 160 200180 220 240 295