Datasheet
www.recom-power.com
REV.: 2/2019 L-3
AC/DC Converter
Specifications (measured @ Ta= 25°C, 240VAC and rated Iout)
RACD04
Series
SAFETY AND CERTIFICATIONS
Certificate Type Report Number Standard
ETL Standard for LED Equipment for use in Lighting Products
160428123GZU-001
UL8750, 2nd Edition, 2015
LED Equipment for Lighting Applications CSA C22.2 No. 250.13, 2014-07-01
Lamp Controlgear: General Requirements for Safety (LVD)
366910
EN61347-1:2015
Lamp Controlgear: Particular Requirements for d.c. or a.c. (LVD) EN61347-2-13:2014 +A1 2017
Lamp Controlgear: General Requirements for Safety (CB Scheme) IEC61347-1:2015, 3rd Edition + A1:2017
Lamp Controlgear: Particular Requirements for d.c. or a.c. (CB Scheme) IEC61347-2-13:2014 2nd Edition +A1:2016
Lamp Controlgear: General Requirements for Safety AS/NZS61347.1:2016
Lamp Controlgear: Particular Requirements for d.c. or a.c. AS/NZS61347.2.13:2013
Lamp Controlgear General Requirements for Safety (ENEC)
366910-1
EN61347-1:2015
Lamp Controlgear Particular Requirements for d.c. or a.c. (ENEC) EN61347-2-13:2014 + A1:2017
D.C. or A.C. Controlgears for LED Performance Requirements (ENEC) EN62384:2006 + A1:2009
D.C. or A.C. Controlgears for LED Performance Requirements IEC62384:2006, 1st Edition +A1:2009
EAC RU-AT.49.09571 TP TC 004/2011
RoHS2 LCS1606201548R RoHS-2011/65/EU + AM-2015/863
EMI Compliance Standard / Criterion
Equipment for general Lighting Purpose EMC Immunity Requirements
366910
EN61547: 2009
Limits and methods of measurement of radio disturbance characteristics of electrical lighting
and similar equipment
EN55015:2013 + A1:2015
Assessment of lighting equipment related to human exposure to electromagnetic fields
EN62493: 2015
ESD Electrostatic discharge immunity test
Air: ±8, 4, 2kV
Contact: ±4, 2kV
EN61000-4-2: 2009, Criteria A
Radiated, radio-frequency, electromagnetic field immunity test
3V/m EN61000-4-3: 2006 + A2:2010, Criteria A
Fast Transient and Burst Immunity
AC Port: ±1kV
DC Port: ±0.5kV
EN61000-4-4: 2012, Criteria A
Surge Immunity
AC Port: ±0.5kV EN61000-4-5: 2014, Criteria A
Immunity to conducted disturbances, induced by radio-frequency fields
3V EN61000-4-6: 2014, Criteria A
Voltage Dips and Interruptions
>95% reduction, 10ms
30% reduction, 200ms
EN61000-4-11, 2004, Criteria B
EN61000-4-11, 2004, Criteria B
Voltage Fluctuations and Flicker in Public Low-Voltage Systems <=16A per phase
EN61000-3-3: 2013 Clause 5
DIMENSION and PHYSICAL CHARACTERISTICS
Parameter
Type
Value
Material
Case
Potting
Plastic (UL94 V-2)
Silicone (UL94 V-0)
Package Dimension (LxWxH) 38.0 x 27.0 x 21.0mm
Package Weight 40g
continued on next page