Datasheet

www.recom-power.com
REV.: 2/2019 L-2
AC/DC Converter
Specifications (measured @ Ta= 25°C, 240VAC and rated Iout)
RACD04
Series
REGULATIONS
Parameter Condition Value
Output Current Accuracy ±5% max.
Line Regulation 5% max.
Load Regulation 5% max.
PROTECTION
Parameter Condition Value
Input Overcurrent Protection internal 0.22W fusible resistor
Open Circuit Protection (OCP)
auto recovery after fault condition is removed
Over Load Protection (OLP)
auto recovery after fault condition is removed
Over Voltage Protection (OVP)
auto recovery after fault condition is removed
Over Temperature Protection (OTP) 110°C Tcase
auto recovery after fault condition is removed
Isolation Voltage
(2)
I/P to O/P 3.75kVAC / 1 minute
Isolation Resistance 100MW
Maximum loading of automatic circuit breakers
Circuit Breaker Circuit Breaker Current
Typ 10A 16A 20A 25A
C 54 118 148 184
Circuit Breaker Circuit Breaker Current
Typ 10A 16A 20A 25A
B 17 28 35 44
C 27 59 74 92
@ 115VAC, 1Ohm, 90° phase angle and max. load @ 230VAC, 1Ohm, 90° phase angle and max. load
Notes:
Note2: For repeat Hi-Pot testing, reduce the time and/or the test voltage
ENVIRONMENTAL
Parameter
Condition
Value
Operating Temperature Range -20°C to +50°C
Maximum Case Temperature +79°C
Operating Altitude 2000m
Operating Humidity 5% to 85% RH, non-condensing
IP Rating IP65
Pollution Degree PD2
Design Lifetime 30 x 10³ hours
Derating Graph
-20 -10 0 10 20 30 40 50 60
100
80
60
40
90
70
50
30
20
10
0
Output Load [%]
Ambient Temperature [°C]