Datasheet

www.recom-power.com
REV.: 1/2018 PA-2
AC/DC Converter
Specifications (measured at Ta= 25°C, full load otherwise noted)
RAC05-C
Series
BASIC CHARACTERISTICS
Parameter Condition Min. Typ. Max.
Input Voltage Range
(5)
nom. Vin = 230VAC 80VAC
115VDC
264VAC
370VDC
Input Current
115VAC
230VAC
110mA
70mA
Inrush Current <2ms
115VAC
230VAC
30A
60A
No load Power Consumption 250mW
Input Frequency Range AC Input 47Hz 440Hz
Minimum Load 0%
Hold-up time 115VAC 10ms
Internal Operating Frequency 100% load at nominal Vin 132kHz
Output Ripple and Noise
(6)
20MHz BW
3.3Vout
all others
120mVp-p
150mVp-p
Efficiency vs. Load
Vin=115VAC Vin=230VAC
0 10 20 30 40 50 60 70 80 90 100
100
80
60
40
90
70
50
30
20
10
0
Efficiency [%]
Output Load [%]
24Vout
12Vout
5Vout
0 10 20 30 40 50 60 70 80 90 100
100
80
60
40
90
70
50
30
20
10
0
Efficiency [%]
Output Load [%]
24Vout
12Vout
5Vout
Notes:
Note5: Refer to line derating graph on page PA-3
Note6: Measurements are made with a 0.1µF MLCC across output (low ESR)
REGULATIONS
Parameter Condition Value
Output Accuracy ±2.0% max.
Line Regulation low line to high line ±0.3% typ.
Load Regulation
(7)
5% to 100% load 0.5% typ.
Notes:
Note7: Operation below 5% load will not harm the converter, but specifications may not be met