Datasheet
www.recom-power.com
REV.: 3/2019 PA-3
AC/DC Converter
Specifi cations (measured at Ta= 25°C, nominal input voltage, full load otherwise noted)
RAC04-C
Series
ENVIRONMENTAL
Parameter Condition
Value
Operating Temperature Range @ natural convection 0.1m/s
full load -25°C to +60°C
refer to derating graph -25°C to +85°C
Maximum Case Temperature +100°C
Operating Altitude 2000m
Operating Humidity non-condensing 95% RH max.
MTBF according to MIL-HDBK-217F, G.B. +25°C 500 x 10
3
hours
-25 -20 0 20 40 60 80 100
100
80
60
40
90
70
50
30
20
10
0
Output Load [%]
Ambient Temperature [°C]
75
25
70 85
100
80
60
40
90
70
50
30
20
10
0
Output Load [%]
Input Voltage [VAC]
80 130 180 230 280
85
90 264
Derating Graph
(@ Chamber and natural convection 0.1m/s)
Line Derating
SAFETY AND CERTIFICATIONS
Certifi cate Type (Safety) Report / File Number Standard
Information Technology Equipment - General Requirments for Safety SPCLVD1606038
IEC60950-1:2005 2nd Edition + 2:2013
EN60950-1:2006 + A2:2013
Information Technology Equipment - General Requirments for Safety
(CB Scheme)
L0339m10-CB-1-B1
IEC60950-1:2005 2nd Edition + A2:2013
Information Technology Equipment - General Requirments for Safety EN60950-1:2006 + A2:2013
Information Technology Equipment - General Requirments for Safety E224736-A5-UL
CAN/CSA-C22.2 No. 60950-1-07, 2nd Edition, 2007
UL No. 60950-1, 2nd Edition, 2007
EAC Safety of Low Voltage Equipment RU-AT.49.09571 TP TC 004/2011
RoHS 2+ RoHS-2011/65/EU + AM-2015/863
EMC Compliance Condition Standard / Criterion
Electromagnetic compatibility of multimedia equipment – Emission Requirements
EN55032:2015, Class B
Information technology equipment - Immunity characteristics - Limits and
methods of measurement
EN55024:2010 + A1:2015
ESD Electrostatic discharge immunity test Air ±8.0kV; Contact ±4.0kV IEC61000-4-2:2008, Criteria A
Radiated, radio-frequency, electromagnetic fi eld immunity test 3V/m IEC61000-4-3:2006 + A2:2010, Criteria A
Fast Transient and Burst Immunity AC Power Port: ±1.0kV IEC61000-4-4:2012, Criteria A
Surge Immunity AC Power Port: L-N ±1.0kV IEC61000-4-5:2005, Criteria A
continued on next page