Datasheet

www.recom-power.com
REV.: 1/2018 PA-4
AC/DC Converter
Specifications (measured at Ta= 25°C, nominal input voltage, full load otherwise noted)
RAC01-C
RAC02-C
PROTECTIONS
Parameter Type Value
Short Circuit Protection (SCP) below 100mW Hiccup mode, automatic recovery
Over Voltage Category OVCII
Class of Equipment Class II
Isolation Voltage
I/P to O/P rated for 1 minute 3kVAC
Isolation Resistance 1G
W
min.
Isolation Capacitance 1000pF max.
Insulation Grade reinforced
Leakage Current 0.25mA max.
continued on next page
Notes:
Note7: Refer to local wiring regulations if input over-current protection is also required
Note8: An external MOV is recommended for operation 230VAC. The Varistor should comply with IEC-61051-2. e.g. EPCOS S14 Series
16
12
8
4
14
10
6
2
-2
Deviation [%]
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
115VAC
230VAC
0
RAC02-05SC
6
5
3
1
4
2
0
-2
Deviation [%]
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
115VAC
230VAC
-1
RAC02-12SC
16
10
6
2
12
8
4
0
-2
Deviation [%]
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
14
115VAC
230VAC
6
4
2
0
5
3
1
-1
-2
Deviation [%]
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
115VAC
230VAC
Deviation vs. Load
RAC01-05SC RAC01-12SC