Datasheet

www.recom-power.com
REV.: 1/2018 PA-5
AC/DC Converter
Specifications (measured at Ta= 25°C, nominal input voltage, full load otherwise noted)
RAC01-C
RAC02-C
ENVIRONMENTAL
Condition
Value
Operating Temperature Range @ natural convection 0.1m/s
full load
RAC01-C -25°C to +80°C
RAC02-C -25°C to +75°C
refer to derating graph -25°C to +85°C
Maximum Case Temperature +95°C
Temperature Coefficient +25°C to +75°C 0.1%°C
Thermal Impedance 0.1m/s, horizontal 27°C/W
Operating Altitude 2000m
Operating Humidity non-condensing 95% RH max.
Pollution Degree PD2
Vibration according to MIL-STD-810F
MTBF according to MIL-HDBK-217F, G.B.
+25°C
+55°C
+80°C
666 x 10
3
hours
395 x 10
3
hours
125 x 10
3
hours
-25 -10 5 20 35 50 65 80 110
100
80
60
40
90
70
50
30
20
10
0
Output Load [%]
Ambient Temperature [°C]
95
8575
RAC02-C
RAC01-C
Derating Graph
(@ Chamber and natural convection 0.1m/s)
Notes:
Note9: Start-up is only guaranteed at temperatures down to -25°C; otherwise specifications may not be met
U
FUSE
L N
Protection Circuit for AC/DC Components (RAC‘s) + >230VAC operation (277VAC)
Protection Circuit