Datasheet

www.recom-power.com
REV.: 1/2019 ECO-4
DC/DC Converter
Specifications (measured @ Ta= 25°C, nominal input voltage, full load unless otherwise specified)
R2SX
Series
ENVIRONMENTAL
Parameter Condition
Value
Operating Temperature Range @ natural convection and full load (refer to “Derating Graph” ) -40°C to +75°C
Operating Altitude 5000m
Operating Humidity non-condensing 5% - 95% RH max.
Pollution Degree PD2
Vibration according to MIL-STD-202G
MTBF according to MIL-HDBK-217F, G.B.
+25°C
+75°C
12100 x 10³ hours
4400 x 10³ hours
Derating Graph
(@ Chamber)
-40 -20 0 20 40 7060-30 -10 10 30 50 80 90
75 85
110100
100
80
75
60
40
90
70
50
30
20
10
0
Output Load [%]
Ambient Temperature [°C]
natural convection (0.1m/s)
0.5m/s forced air
SAFETY AND CERTIFICATIONS
Certificate Type (Safety) Report / File Number Standard
Audio/video, information and communication technology equipment - Safety
requirements
E224736
UL62368-1, 2nd Edition, 2014
CAN/CSA -C22.2 No. 62368-1-14, 2nd Edition
Information Technology Equipment, General Requirements for Safety
UL60950-1, 2nd Edition, 2014
CAN/CSA-C22.2 No. 60950-1-07, 2nd Edition
Audio/video, information and communication technology equipment - Safety
requirements (CB Scheme)
WD-ITAV-190016-A0
IEC62368-1:2014, 2nd Edition
Audio/video, information and communication technology equipment - Safety
requirements
EN62368-1:2014 + A11:2017
RoHS2 RoHS 2011/65/EU + AM2015/863
continued on next page