Datasheet
www.recom-power.com
REV.: 1/2019 ECO-3
DC/DC Converter
Specifications (measured @ Ta= 25°C, nominal input voltage, full load unless otherwise specified)
R2SX
Series
REGULATIONS
Parameter Condition Value
Output Accuracy ±5.0% max.
Line Regulation low line to high line ±1.2% typ. at 1.0% of Vin typ.
Load Regulation
(6)
10% to 100% load
3.3Vout, 5Vout
12Vout 15Vout, 24Vout
15.0% max.
10.0% max.
Notes:
Note6: Operation below 10% load will not harm the converter, but specifications may not be met
Tolerance Envelope
R2SX-05xx(/H)
R2SX-12xx(/H)
R2SX-24xx(/H)
+10%
+6%
Vnom
+5%
-1%
-5%
Output Voltage [%]
10 50 100
Output Load [%]
Typical Load Line
+10%
+5%
Vnom
+5%
-0.5%
-5%
Output Voltage [%]
10 50 100
Output Load [%]
Typical Load Line
+15%
+9%
Vnom
+5%
-1.5%
-5%
Output Voltage [%]
10 50 100
Output Load [%]
Typical Load Line
PROTECTIONS
Parameter Type Value
Isolation Voltage
I/P to O/P standard
tested for 1 second
rated for 1 minute
(7)
1kVDC
500VAC
I/P to O/P with suffix “/H”
tested for 1 second
rated for 1 minute
(7)
3kVDC
1.5kVAC
Isolation Resistance 10GΩ min.
Isolation Capacitance
100pF max.
Insulation Grade functional
Notes:
Note7: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Note8: Refer to local safety regulations if input over-current protection is also required. Recommended fuse: slow blow type