Datasheet
E-44
www.recom-electronic.com
REV: 2/2011
R2S-R2D
R2S & R2D
Series
ECONOLINE
DC/DC-Converter
Specifications - Continued
Typical Characteristics
Efficiency %
100
0
40%0% 100%
40
Efficiency / Load
60%
80%
20%
20
60
80
Total Output current (%)
2405
1205
0505
Deviation / Load
-10.000
40%0% 100%
Deviation from Nominal (%)
60%
80%
20%
-5.000
Total Output current (%)
0505
0.000
5.000
10.000
15.000
20.000
25.000
1205
2405
R2S-xx05
Isolation Voltage (tested for 1 second) 1000VDC
(rated for 1 minute) 500VAC / 60Hz
Isolation Voltage (rated for 1 minute) 3000VDC
(rated for 1 minute) 1500VAC / 60Hz
Isolation Capacitance 20pF min. / 115pF max.
Isolation Resistance 10 GΩ min.
Short Circuit Protection 1 Second
P-Suffix Continuous
Operating Temperature Range (free air convection) -40°C to +100°C (see Graph)
Storage Temperature Range -55°C to +125°C
Reflow Temperature ROHS compliant 245°C (30 sec), peak 255°C (5 sec) max.
Vapour Phase Process (for more details see Application Notes) 230°C (90 sec) max.
Relative Humidity 95% RH
Package Weight R2S, R2S8 1.4g
R2D, R2D10 1.5g
R2S12, R2D12 1.6g
Packing Quantity R2S, R2S8 39 pcs per Tube
R2S12, R2D, R2D10, R2D12 33 pcs per tube
All Types 250 pcs per Reel
MTBF (+25°C) using MIL-HDBK 217F 4351 x 10
3
hours
(+85°C) using MIL-HDBK 217F 1363 x 10
3
hours
Certifications
CB Test Report Report: US/14402/UL
UL General Safety Report: E224736 UL 60950-1 1st Ed.
CUL General Safety C22.2 No. 60950-1-03
EN General Safety EN-60950-1 2rd Ed.
EN Medical Safety Report: MDD 1005061 EN60601-1: 1990 + A13:1996
EN General Safety Report: LVD 1005061 EN60950-1: 2006 2nd Ed. +A11:2009
}
Detailed Information see
Application Notes chapter "MTBF"
Efficiency %
100
0
40%0% 100%
40
Efficiency / Load
60%
80%
20%
20
60
80
Total Output current (%)
2405
1205
0505
Deviation / Load
-10.000
40%0% 100%
Deviation from Nominal (%)
60%
80%
20%
-5.000
Total Output current (%)
0505
0.000
5.000
10.000
15.000
20.000
25.000
1205
2405
R2D-xx05
Output Power (%)
100
60
20
40
105
500-40 150
Operating Temperature °C
0
80
Safe Operating Area
100
Derating-Graph
(Ambient Temperature)
The derating graph is valid only for the shown part
numbers.
R2S-0505, R2D-0505
Notes
Note 1 Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter.