Datasheet

www.recom-power.com
REV.: 5/2019 ECO-6
DC/DC Converter
Specifications (measured @ Ta= 25°C, nominal Input and full load after warm-up time unless otherwise noted)
RxxP2xxyy
Series
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer.
The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or
cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the
unauthorized
use of RECOM products in such safety-critical applications.
INSTALLATION AND APPLICATION
C1
R
1
Signal+
Signal-
R
2
Q1
D1
S
D
G
D3
R
5
R
4
R
3
D2
C3
C2
+V
in
-V
in
+V
in
-V
in
+V
out
-V
out
OPTO COUPLER
SIC Mosfet
IN OUT
Regulator
SIC
MOSFET
DRIVER
IC2
IC3
IC1
+
PACKAGING INFORMATION
Packaging Dimension (LxWxH) tube 520.0 x 22.3 x 12.0mm
Packaging Quantity 25pcs
Storage Temperature Range -55°C to +125°C
Storage Humidity 5-95% RH max.
Typical Application Circuit
Dimension Drawing (mm)
1 2
5 6 7
1 2
5 6 7
Bottom View
Top View
0.51
2.4 12.5
0.50
+0.10/-0.05
9.819.5
6x2.54= 15.24
3x2.54= 7.62
1.9
2.54
2.54
4.10
0.25
±0.05
Marking
embossed logo
Recommended Footprint Details
Pin Connections
Pin # Dual
1 +Vin
2 -Vin
5 -Vout
6 Com
7 +Vout
Tolerance: xx.x= ±0.5mm