Datasheet
+10%
+5%
V Nom.
+5%
1.5%
10% 50% 100%
Output Voltage
Output Load Current (%)
5%
Typical Load Line
RxxP2xx/R
ECONOLINE
DC/DC-Converter
Operating Temperature Range (free air convection) -40°C to +85°C (see Graph)
Storage Temperature Range -55°C to +125°C
Relative Humidity 95% RH
Package Weight 4.3g
Packing Quantity 25 pcs per Tube
Potting Material Silicone Rubber Compound (UL94V-0)
MTBF (+25°C) 1154 x 10
3
hours
. (+85°C) Reinforced 168 x 10
3
hours
Reinforced Isolation Transformer Creepage Reinforced Types 5.5 mm min.
Transformer Clearance Reinforced Types 5.5 mm min.
PCB Creepage & Clearance Reinforced Types 4.6 mm min.
Certifications
Measurement, Control and Laboratory Use Safety Report: T1301251-313 EN 61010-1 : 2010
CSA General Safety Report: 2207629 UL 60950-1 1st Edition
C22.2 No. 60950-1-03
UL/cUL Medical Safety Report: 314885-A5 UL60601-1 1st Edition
CSA Medical Safety Report: 2207629 CAN/CSA-22.2 No 601.1-M90
EN General Safety Report: SPCLVD1310079-1 EN60950-1 : 2006
CB/EN Medical Safety Report: CA-10169-A1-UL IEC/EN 60601-1 3rd Edition
ANSI/AAMI Medical Safety Report: E314885-A5 ES60601-1 3rd Edition
Specifications (measured at T
A
= 25°C, nominal input voltage, full load and after warm-up)
Tolerance Envelope
}
Detailed Information see
Application Notes chapter "MTBF"
Notes
Note 1 Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter.
RxxP2xxS_D
/Rx Series
REV: 2/2015 E-101www.recom-power.com
Typical Characteristics
RxxP205S/R6.4 and RxxP205S/R8
Efficiency %
100
0
40%0% 100%
40
Efficiency / Load
60%
80%
20%
20
60
80
Total Output current (%)
R05P205S/R6.4
R24P205S/R6.4
R12P205S/R6.4
Deviation / Load
-10.000
40%0% 100%
Deviation from Nominal (%)
60%
80%
20%
-5.000
Total Output current (%)
R24P205S/R6.4
0.000
5.000
10.000
15.000
20.000
25.000
R05P205S/R6.4
R12P205S/R6.4