Datasheet
E-36
www.recom-electronic.com
REV: 1/2011
RxxPxx(/R)
Typical Characteristics
Efficiency %
100
0
40%0% 100%
40
Efficiency / Load
60%
80%
20%
20
60
80
Total Output current (%)
R05P09S
R12P05S
R12P09S
R05P05S
Deviation / Load
-10.000
40%0% 100%
Deviation from Nominal (%)
60%
80%
20%
-5.000
Total Output current (%)
R05P05S
0.000
5.000
10.000
15.000
20.000
25.000
R12P05S
R05P09S
R12P05D
RxxP05/09S
RxxP05/09D
ECONOLINE
DC/DC-Converter
ECONOLINE
DC/DC-Converter
Efficiency %
100
0
40%0% 100%
40
Efficiency / Load
60%
80%
20%
20
60
80
Total Output current (%)
R05P09D
R12P09D
R12P05D
R05P05D
Deviation / Load
-10.000
40%0% 100%
Deviation from Nominal (%)
60%
80%
20%
-5.000
Total Output current (%)
R05P05D
0.000
5.000
10.000
15.000
20.000
25.000
R12P05D
R05P09D
R12P09D
MTBF (+25°C) using MIL-HDBK 217F 2974 x 10
3
hours
(+85°C) using MIL-HDBK 217F 728 x 10
3
hours
Reinforced Isolation
Transformer Clearance Reinforced Types 5.5 mm min.
PCB Creepage & Clearance Reinforced Types 4.8 mm min.
Certifications CB Report: Medical Safety Ref: CA/11158/CSA IEC60601-1:1988 + A1: 1991 + A2:1995
Reinforced Part CSA Medical Safety Report: 227629 C22.2 601-1 2nd Ed.
UL 60601-1 1st Ed.
CSA General Safety Report: 2219431 C22.2 No. 60950-1-03
UL 60950-1 1st Ed.
Recognised as Reinforced Isolation Supplement to Report: 2219431
Measurement, Control and Laboratory Use Safety Report: IL091212010M1 EN 61010-1 : 2001
Certifications UL General Safety Report: E248550 UL 60950-1 1st Ed.
Standard Part C22.2 No. 60950-1-03
EN General Safety Report: PS-R7219C1 EN60950-1:2001 + A11: 2004
EN Medical Safety Report: PS090301601 EN60601-1:1990 + A13: 1996
Specifications (continued)Tolerance Envelope
+10%
+5%
V Nom.
+5%
1%
10% 50% 100%
Output Voltage
Output Load Current (%)
5%
Typical Load Line
RxxPxxS_D
(Rx) Series
}
Detailed Information see
Application Notes chapter "MTBF"
Notes