Datasheet
www.recom-power.com
REV.: 4/2019 I-6
DC/DC Converter
Specifications (measured @ Ta= 25°C, 10% minimum load, unless otherwise stated) 
R-78Bxx-1.0(L)
Series
Dual Output (two Converters) with Negative Output
Selection Guide - Negative Output
Notes:
  Note5:  Maximum Capacitive Load including C2 is 220µF
Part  Input  Output  Output   Efficiency   External Capacitor
Number  Voltage Range  Voltage  Current  @ min Vin    @ max. Vin  C1    C2 
(5)
  [VDC]  [VDC]  [A]  [%] [%]
R-78B1.5-1.0  4.75 - 28  -1.5  -0.6  70    68  10µF/50V    22µF/6.3V
R-78B1.8-1.0  4.75 - 28  -1.8  -0.6  72    72  10µF/50V    22µF/6.3V
R-78B2.5-1.0  4.75 - 28  -2.5  -0.6  75    77  10µF/50V    22µF/6.3V
R-78B3.3-1.0  4.75 - 28  -3.3  -0.6  77 80  10µF/50V  22µF/6.3V
R-78B5.0-1.0  6.5 - 28  -5.0  -0.6  83 85  10µF/50V 22µF/10V
R-78B6.5-1.0  8.0 - 26  -6.5  -0.4  84    87  10µF/50V    10µF/10V
R-78B9.0-1.0  8.0 - 18  -9.0  -0.4  88    89  10µF/25V    10µF/25V
R-78B12-1.0  8.0 - 18  -12  -0.3  89 90  10µF/25V 10µF/25V
R-78B15-1.0  8.0 - 18  -15  -0.3  89 91  10µF/25V 10µF/25V
continued on next page
High Efficiency Multiple Output
Application Examples
C2
C2
C1
C1
+V
in
GND
+V
in
-V
in
-12V @ 84mA
+12V @ 84mA
0V Com
RD-0512D
RP10-4812SEW
+5V @ 0.4A
+12V @ 0.1A
+5V @ 1A
+3.3V @ 1A
0V @ 1A
• Wide input range 4.75V to 34V
• ±12V outputs for analogue circuits, e.g. instrumentation amplifier
• +5V output for digital circuits
- High isolation voltage - 1.6kV
- Improved load / line regulation
- Wide input voltage range - 18~75VDC
- Point-of-load architecture
- C1 is required. Further decoupling filtering
 may be necessary between the converters
C1 optional;
C2 required (further decoupling filtering may 
be necessary between the two converters)
C2, C3: optional
C3
R-78Bxx-1.0
GND
+V
out
+V
in
R-78B5.0-1.0
GND
+V
out
+V
in
R-78B3.3-1.0
GND
+V
out
+V
in
+V
in
-V
out
C2
C1
GNDGND
R-78Bxx-1.0
2
31
+V
in
-V
out
C2
C1
+V
out
GNDGND
R-78Bxx-1.0
2
31
R-78Bxx-1.0
2
31