Datasheet
L-48 www.recom-electronic.com
REV: 2/2013
RACD150
LIGHTLINE
AC/DC-Converter
with 5 Year Warranty
150 Watt
Single
Output
Selection Guide
Input Voltage Range 90-305 VAC or 127-430VDC
Input Frequency Range 47-63Hz.
Power Factor Full Load, 115VAC >0.98
Full Load, 230VAC >0.95
Full Load, 277VAC >0.94
AC Current 115VAC 2A max.
230VAC 1A max.
Input / Output Isolation 3.75kVAC
Input / Case Isolation 1.8kVAC
Output / Case Isolation 0.5kVAC
Leakage Current 230VAC <0.5mA
Current Tolerance ±5%
Voltage Tolerance -1% to 5%
Set up Time 115VAC 1.0s
(@ Full Load) 230VAC / 277VAC 0.8s
Ripple & Noise 48V Version 200mV max.
others 150mV max.
(with 20MHz bandwidth & 47μF Elco + 0.1μF MLCC)
Over Current Protection 95%-105% rated current Auto-Recovery
Short Circuit Protection Hiccup Mode
Over Voltage Protection 12V 12.5V typ.
Latch Mode 24V 24.5V typ.
(Power off to recover) 36V 36.5V typ.
48V 48.5V typ.
Over Temperature Protection Tcase 95°C ±10°C
Operation Temperature (Refer to Output Load Derating Curve) -30°C to +70°C
Operation Humidity 20%-90% RH Non-Condensing
Storage Temperature -40°C to +80°C
Storage Humidity 10%-90% RH
Vibration 2G 10min/1Cycle, Period for 60 min 10-500Hz
IP Rating IP67
Safety Standards UL/cUL LED Lighting Safety (E340696) cUL8750
CE LVD Directive, Safety EN61347-2-13
EMC Standards EMC Compatibility EN55015
FCC, Part 15
Harmonic Current EN61000-3-2 Class C (
≥75% load)
EN61000-3-3
EMC Immunity EN61000-4-2, 3, 4, 5, 6, 11
Dimension 199.2*68*39mm
Weight 940g
MTBF using MIL-HDBK-217F (25°C) 200 x 10³ hours
Design Lifetime 70 x 10³ hours
Specifications
● Universal AC Input
● Constant Voltage / Constant Current Operation
● CE and UL Certified Class 1 LED Driver
● Active Power Factor Correction
● IP67 Design for Indoor and Outdoor Use
● Cooling by Free Air Convection
Features
LED DRIVER
Part CV Mode CC Mode Efficiency
Constant Voltage Current Range DC Voltage Range Constant Current (230VAC)
(V) (A) (V) (A) (typ.)
RACD150-12 12 0-11 9-12 11 88%
RACD150-24 24 0-6.3 14-24 6.3 90%
RACD150-36 36 0-4.2 26-36 4.2 90%
RACD150-48 48 0-3.2 34-48 3.2 90%
UL 8750 Certified
EN 61347 Certified
E340696
RoHS
2011/65/EU
6/6
Note:
The use of a circuit breaker with
C-characteristic is recommended.