Quality Beyond Expectations

11
© 2012 REC All rights reserved. Confidential © 2012 REC All rights reserved. Confidential
Pushing the standards
Test
IEC 61215
& IEC 61730
UL 1703 REC
Mechanical load 5400 Pa
5400 Pa
(Rated to 3600 Pa)
Test to failure
Modules are tested in
excess of 10,000 Pa
Thermal cycling 200 cycles 200 cycles 400 cycles
Damp heat 1000 hours n/a 2000 hours
Humidity freeze 10 cycles 10 cycles
20 cycles to 40 cycles
(dependent on component change)
Reverse current overload
135 % of series fuse
rating current
135 % of series fuse
rating current
135 % of series fuse
rating current
UV 20 kWh pre-conditioning NA
30 kWh pre-conditioning
Component level testing
of UV for reliability
Combined cycle n/a n/a 2 cycles
REC is not satisfied with simply passing the standards, so has created its own
stringent internal testing procedure. The table below shows how REC’s stringent
internal qualification protocol compares to international standards: