Peak Energy Installation Manual
GR
GR
GR GR
GR
-
+
REC Peak Energy Series Installation Manual - UL
Rev K. .
Fig. : Drainage holes
v) Drainage holes
There are eight drainage holes, . x . in ( x . mm) in the panels frame, each spaced . in ( mm) from the corner of the panel frame (fig. ).
This allows water caused by rain or snow melt to exit the frame easily and minimizes the damage caused by freezing and thawing. Ensure these holes are
not covered by any part of the mounting structure.
Part Name Material Specification
Bolt ASTM F (stainless steel) /” x - /”
Flange Nut ASTM F (stainless steel) /” x
When using mounting holes, fixings must be fastened to -lbs ( Nm) of torque and installation must be according to fig. .
Install the above parts as shown in fig. . Consult the Unirac Code Compliant Installation Manual for further details where necessary. For
areas where discrepancy may exist, this installation manual shall take precedence.
iii) Mounting holes
Mounting utilizing the four elongated holes (. x . in (. x mm)) on the underside of the panel frame (at a distance of . in ( mm) from the
midpoint of the long side) have been found to comply with UL requirements for a maximum design load of . lbs/ ( Pa) (fig. ).
When mounting using mounting holes, the frame and panel edge must be supported by two transverse rails (fig. , p ), of aluminium or galvanized
steel to avoid galvanic corrosion and be appropriate for the local environment. These must be held in position by bolts and flange nuts according to the
specifications below. If bought in a kit, do not use the washers and boom mounted clips provided:
Observe the following procedures when using mounting holes (fig. ):
• Additional electrical bonding to Earth is required for the support structure see page .
• All four mounting holes in the frame must be used (for long or short-sided mounting orientation).
• Fixings must be tightened to -lbs ( Nm) using a torque wrench.
The warranty will be voided if additional holes are made in the frame. All fixing and fastening materials should be corrosion resistant.
Mounting
holes
Fig. : Mounting holes Fig. : Mounting using
mounting holes
iv) Slide-in Systems
REC Peak Energy panels have not been certified by UL for use with slide-in type mounting systems. If you have any questions regarding a mounting system
and its suitability for REC Peak Energy panels, please contact your local office for technical support.
38
GR
GR
GR
GR
28
1665±2,5
900
382,5
950
991±2,5
17
45
11±0,2
6,6±0,2
20,5±0,5