Instruction Manual
Table Of Contents
- CONTENTS
- INTRODUCTION
- SAFETY MEASURES
- PANEL HANDLING
- CHOOSING AN INSTALLATION LOCATION
- ELECTRICAL INSTALLATION
- MECHANICAL INSTALLATION
- PANEL INSTALLATION
- Securing of Panels
- Installation of REC TwinPeak 4 Series panels
- Installation of REC TwinPeak 5 Series panels
- Installation of REC N-Peak 2 Series panels
- Installation of REC N-Peak 3 Black Series panels
- Mounting methods: Slide in systems
- Mounting methods: Mounting holes
- Mounting methods: Six-point mounting
- Drainage holes
- CONNECTIONS AND CONNECTORS
- CABLE MANAGEMENT
- PANEL MAINTENANCE
- RECYCLING
- DISPOSAL OF OLD ELECTRICAL AND ELECTRONIC EQUIPMENT
- PANEL CHARACTERISTICS
- ANNEX 1: INSTALLATIONS ON WATER PLATFORMS
- ANNEX 2: INSTALLATIONS USING MODULE LEVEL POWER ELECTRONICS
- EC DECLARATION OF CONFORMITY
- UKCA DECLARATION OF CONFORMITY
- DOCUMENT HISTORY
- Fig. 1: Clamp specifications
- Fig. 2: Panel quarter divisions
- Fig. 3: Clamping of REC TwinPeak 4 Series panels with rails parallel to short side of the panel
- Fig. 4: Clamping of REC TwinPeak 4 Series panels with rails parallel to long side of the panel
- Fig. 5: Clamping of REC TwinPeak 4 Series panels using short rails
- Fig. 6: Clamping of REC TwinPeak 5 Series panels with rails parallel to short side of the panel
- Fig. 7: Clamping of REC TwinPeak 5 Series panels with rails parallel to long side of the panel
- Fig. 8: Clamping of REC TwinPeak 4 Series panels using short rails
- Fig. 9: Clamping of REC N-Peak 2 Series panels with rails parallel to short side of the panel
- Fig. 10: Clamping of REC N-Peak 2 Series panels with rails parallel to long side of the panel
- Fig. 11: Clamping of REC N-Peak 2 Series panels using short rails
- Fig. 12: Clamping of REC N-Peak 3 Black Series panels with rails parallel to short side of the panel
- Fig. 13: Clamping of REC N-Peak 3 Black Series panels with rails parallel to long side of the panel
- Fig. 14: Clamping of REC N-Peak 3 Black Series panels using short rails
- Fig.15: Mounting holes
- Fig. 16: Device specifications for mounting holes
- Fig. 17: Mounting hole installation example
- Fig. 18: Six-point mounting configuration clamping zones
- Fig. 19: Drainage and grounding holes
- Fig. 20: Minimum cable bend radius
- Fig. 21: WEEE symbol
- Fig. 22: Panel dimensions: REC TwinPeak4 Series
- Fig. 23: Panel dimensions: REC TwinPeak 4 Black Series
- Fig. 24: Panel dimensions: REC TwinPeak 5 Series
- Fig. 25: Panel dimensions: REC TwinPeak 5 Black Series
- Fig. 26: Panel dimensions: REC N-Peak 2 Series
- Fig. 28: Panel dimensions: REC N-Peak 3 Black Series
- Fig. 29: MLPE device installation zones
REC Installation Manual - REC Solar Panels - IEC /
Rev N . Ref: PMIM
ANNEX : INSTALLATIONS USING MODULE LEVEL POWER ELECTRONICS
This section is applicable to all REC products referred to in this installation manual.
Module Level Power Electronics (MLPE) is the name given to the range of panel-level components that can be installed in PV system circuits
installed on or in buildings to reduce shock hazard for emergency responders. MLPE devices can be supplied pre-installed by panel manufacturers
or as a ‘retro-fit’ system made by third-party manufacturers.
MLPE devices may be used on REC solar panels where desirable or mandatory (note that the certification testing of solar panels does not include
testing with MLPE devices). When installing an MLPE device on an REC solar panel, follow the instructions provided by the device manufacturer and
the instructions specific for REC solar panels given below. Failure to follow the manufacturer and the REC instructions may invalidate the warranty.
INSTALLATION
i) Installation
• MLPE devices are suitable for use wherever solar panels are suitable for installation. Observe any limitations set by the MLPE manufacturer.
(e.g., minimum mounting gap between MLPE and rooop).
• When aaching an MLPE device to a solar panel, it must be secured to the panel frame. Follow MLPE manufacturer instructions to ensure
optimum mounting of MLPE device and prevent any slippage during operation.
• MLPE devices may also be aached to the mounting construction. In such cases, refer to the instructions provided by the manufacturer.
• Wherever possible, the installation of the MLPE device should not cover the product label on the rear of the panel.
• MLPE
devices may only be installed on REC solar panels in the areas shown in the diagram below (fig. ):
Fig. : MLPE device installation zones
Installation of MLPE device in the green zone is permied.
Installation of MLPE device in the red zone is not permied.
CAUTION
• To avoid damage to the panel and to allow for thermal expansion, there must be a minimum gap of . in (. mm) between the MLPE device
and the panel backsheet.
• The mounting holes in the panel frame must not be used for the installation of MLPE devices.
• The drilling of extra holes in the frame is not permied and will invalidate the panel warranty.
CONNECTION
• First ensure the installation of the MLPE device is secure and safe.
• Following the device manufacturer’s instructions to connect the cables from the MLPE
device to the solar panel correctly (usually positive to
positive [+ to +] and negative to negative [- to -]).
• Connection to the next panel in the array should be done from the ‘free’ cables.
SAFETY
• Immediately disconnect the device if there is a problem during installation.
0 - 480 mm [0 - 18.9 in]
0 - 480 mm [0 - 18.9 in]
0 - 1016 mm [0 - 40 in]
0 - 480 mm [0 - 18.9 in]
0 - 480 mm [0 - 18.9 in]
0 - 1016mm [0 - 40 in]
GR
GR
GR