Instruction Manual
Table Of Contents
- CONTENTS
- INTRODUCTION
- SAFETY MEASURES
- PANEL HANDLING
- CHOOSING AN INSTALLATION LOCATION
- ELECTRICAL INSTALLATION
- MECHANICAL INSTALLATION
- PANEL INSTALLATION
- Securing of Panels
- Installation of REC TwinPeak 4 Series panels
- Installation of REC TwinPeak 5 Series panels
- Installation of REC N-Peak 2 Series panels
- Installation of REC N-Peak 3 Black Series panels
- Mounting methods: Slide in systems
- Mounting methods: Mounting holes
- Mounting methods: Six-point mounting
- Drainage holes
- CONNECTIONS AND CONNECTORS
- CABLE MANAGEMENT
- PANEL MAINTENANCE
- RECYCLING
- DISPOSAL OF OLD ELECTRICAL AND ELECTRONIC EQUIPMENT
- PANEL CHARACTERISTICS
- ANNEX 1: INSTALLATIONS ON WATER PLATFORMS
- ANNEX 2: INSTALLATIONS USING MODULE LEVEL POWER ELECTRONICS
- EC DECLARATION OF CONFORMITY
- UKCA DECLARATION OF CONFORMITY
- DOCUMENT HISTORY
- Fig. 1: Clamp specifications
- Fig. 2: Panel quarter divisions
- Fig. 3: Clamping of REC TwinPeak 4 Series panels with rails parallel to short side of the panel
- Fig. 4: Clamping of REC TwinPeak 4 Series panels with rails parallel to long side of the panel
- Fig. 5: Clamping of REC TwinPeak 4 Series panels using short rails
- Fig. 6: Clamping of REC TwinPeak 5 Series panels with rails parallel to short side of the panel
- Fig. 7: Clamping of REC TwinPeak 5 Series panels with rails parallel to long side of the panel
- Fig. 8: Clamping of REC TwinPeak 4 Series panels using short rails
- Fig. 9: Clamping of REC N-Peak 2 Series panels with rails parallel to short side of the panel
- Fig. 10: Clamping of REC N-Peak 2 Series panels with rails parallel to long side of the panel
- Fig. 11: Clamping of REC N-Peak 2 Series panels using short rails
- Fig. 12: Clamping of REC N-Peak 3 Black Series panels with rails parallel to short side of the panel
- Fig. 13: Clamping of REC N-Peak 3 Black Series panels with rails parallel to long side of the panel
- Fig. 14: Clamping of REC N-Peak 3 Black Series panels using short rails
- Fig.15: Mounting holes
- Fig. 16: Device specifications for mounting holes
- Fig. 17: Mounting hole installation example
- Fig. 18: Six-point mounting configuration clamping zones
- Fig. 19: Drainage and grounding holes
- Fig. 20: Minimum cable bend radius
- Fig. 21: WEEE symbol
- Fig. 22: Panel dimensions: REC TwinPeak4 Series
- Fig. 23: Panel dimensions: REC TwinPeak 4 Black Series
- Fig. 24: Panel dimensions: REC TwinPeak 5 Series
- Fig. 25: Panel dimensions: REC TwinPeak 5 Black Series
- Fig. 26: Panel dimensions: REC N-Peak 2 Series
- Fig. 28: Panel dimensions: REC N-Peak 3 Black Series
- Fig. 29: MLPE device installation zones
REC Installation Manual - REC Solar Panels - IEC /
Rev N . Ref: PMIM
TECHNICAL PROPERTIES: REC TWINPEAK SERIES
Fig. : Panel dimensions: REC TwinPeak Series
GR
GR
GR
GR
11±0.2
[0.43 ±0.1]
6.6±0.2 [0.26 ±0.1]
20.5±0.5
[0.8 ±0.02]
GR
710±3 [27.9 ±0.12]
30 [1.2]
22.5 [0.9]
28 [1.1]
1899±2.5 [74.8 ±0.1]
859 [33.8]
156 [6.14]
156 [6.14]
520[20.5]
999 [39.33]
1200 [47.2]
5.5±0.2
[0.22±0.01]
1200 [47.2]
1040±2.5 [40.94 ±0.1]
17 [0.7]
45 [1.8]
GENERAL DATA
Cell type:
half-cut mono c-Si p-type cells,
strings of cells in series
Glass:
. mm solar glass with anti-reflective surface treatment
in accordance with EN
Backsheet: Highly resistant polymer
Frame:
Anodized aluminum (black)
with silver support bars
Junction box:
-part, bypass diodes, lead-free
IP rated, in accordance with IEC
Connectors:
Stäubli MC PVKBT/KST ( mm)
in accordance with IEC , IP only when connected
Cable:
mm solar cable, . m + . m
in accordance with EN
Dimensions: x x mm (. m
)
Weight: . kg
Origin: Made in Singapore
Measurements in mm [in]
LOW LIGHT BEHAVIOUR
Typical low irradiance performance of module at STC:
WARRANTY
Standard REC ProTrust
Installed by an REC
Certified Solar Professional
No Yes Yes
System Size All ≤ kW kW
Product Warranty (yrs)
Power Warranty (yrs)
Labor Warranty (yrs)
Power in Year
Annual Degradation . . .
Power in Year
See warranty documents for details. Conditions apply
Irradiance (W/m)
Rel. Efficiency ()
TEMPERATURE RATINGS
*
Nominal Module Operating Temperature: .°C (±°C)
Temperature coefficient of P
MAX
: . /°C
Temperature coefficient of V
OC
: . /°C
Temperature coefficient of I
SC
: . /°C
*
The temperature coefficients stated are linear values
CERTIFICATIONS
IEC :, IEC :, UL
IEC PID
IEC Salt Mist
IEC Ammonia Resistance
ISO Ignitability (Class E)
IEC Dynamic Mechanical Load
IEC : Hailstone (mm)
ISO , ISO , IEC , IEC
DELIVERY INFORMATION
Panels per pallet:
Panels per . m truck: ( pallets)
Panels per GP/high cube container ( pallets)
MAXIMUM RATINGS
Operational temperature: ... +°C
Maximum system voltage: V
Maximum test load (front): + Pa ( kg/m)
*
Maximum test load (rear): - Pa ( kg/m)
*
Max series fuse rating: A
Max reverse current: A
*
See installation manual for mounting instructions.
Design load = Test load / . safety factor)
STC NMOT
85
90
95
100
105
200100 300 400 500 600 700 800 900 1000
take-e-way WEEE-compliant
recycling scheme
ELECTRICAL DATA Product Code
*
: RECxxxTP
Power Output - P
MAX
(Wp)
Wa Class Sorting - (W) /+ W /+ W /+ W /+ W /+ W
Nominal Power Voltage - V
MPP
(V) . . . . .
Nominal Power Current - I
MPP
(A) . . . . .
Open Circuit Voltage - V
OC
(V) . . . . .
Short Circuit Current - I
SC
(A) . . . . .
Panel Efficiency () . .
. . .
Power Output - P
MAX
(Wp)
Nominal Power Voltage - V
MPP
(V) . . . . .
Nominal Power Current - I
MPP
(A) . . . . .
Open Circuit Voltage - V
OC
(V) . . . . .
Short Circuit Current - I
SC
(A) . . . . .
Values at standard test conditions (STC: air mass AM ., irradiance W/m, temperature °C), based on a production spread with a
tolerance of P
MAX
, V
OC
& I
SC
± within one wa class. Nominal module operating temperature (NMOT: air mass AM ., irradiance W/m,
temperature °C, windspeed m/s). * Where xxx indicates the nominal power class (P
MAX
) at STC above.