Panel Install manual

Table Of Contents

REC Installation Manual - REC Panels - UL 6
Rev L  . Ref: PMIM
ANNEX : INSTALLATIONS USING MODULE LEVEL POWER ELECTRONICS
This section is applicable to all REC products referred to in this installation manual.
Module Level Power Electronics (MLPE) is the name given to the range of panel-level components that can be installed in PV system circuits installed on
or in buildings to reduce shock hazard for emergency responders. MLPE devices can be supplied pre-installed by panel manufacturers or as a ‘retro-fit’
system made by third-party manufacturers. From January , , Section . of the  National Electrical Code (NEC) (in the U.S.A.) requires
the panel-level rapid shutdown of solar systems (replacing the previous array-level shutdown requirement of NEC ). This means that all conductors
within an array’s . in ( mm) boundary have to be reduced to  V or less within  seconds of rapid shutdown initiation.
MLPE devices may be used on REC solar panels where desirable or mandatory (note that the certification testing of solar panels does not include
testing with MLPE devices). When installing an MLPE device on an REC solar panel, follow the instructions provided by the device manufacturer and the
instructions specific for REC solar panels given below. Failure to follow the manufacturer and the REC instructions may invalidate the warranty.
INSTALLATION
i) Installation
MLPE devices are suitable for use wherever solar panels are suitable for installation. Observe any limitations set by the MLPE manufacturer. (e.g.,
minimum mounting gap between MLPE and rooop).
When aaching an MLPE device to a solar panel, it must be secured to the panel frame. Follow MLPE manufacturer instructions to ensure
optimum mounting of MLPE device and prevent any slippage during operation.
MLPE devices may also be aached to the mounting construction. In such cases, refer to the instructions provided by the manufacturer.
Wherever possible, the installation of the MLPE device should not cover the product label on the rear of the panel.
MLPE devices may only be installed on REC solar panels in the areas shown in the diagram below (fig.  & ):
Fig. : REC -cell panels MLPE device installation zones
Installation of MLPE device in the green zone is permied.
Installation of MLPE device in the red zone is not permied.
CAUTION
To avoid damage to the panel and to allow for thermal expansion, there must be a minimum gap of . in (. mm) between the MLPE device and
the panel backsheet.
The mounting holes in the panel frame must not be used for the installation of MLPE devices.
The drilling of extra holes in the frame is not permied and will invalidate the panel warranty.
CONNECTION
First ensure the installation of the MLPE device is secure and safe.
Following the device manufacturer’s instructions to connect the cables from the MLPE device to the solar panel correctly (usually positive to
positive [+ to +] and negative to negative [- to -]).
Connection to the next panel in the array should be done from the ‘free’ cables.
SAFETY
Immediately disconnect the device if there is a problem during installation.
Fig. : REC -cell panels MLPE device installation zones
0 - 480 mm [0 - 18.9 in]
0 - 480 mm [0 - 18.9 in]
0 - 1016 mm [0 - 40 in]
0 - 480 mm [0 - 18.9 in]
0 - 480 mm [0 - 18.9 in]
0 - 1016mm [0 - 40 in]